EVENT
DESCRIPTION
NUMBER
027
PSC PANEL CONNECTOR
028
CN1 CONNECTOR
AUX BLOWER NOT CONNECTED
029
AT POWER
030
GF CONTACTOR
031
GFR CONTACTOR
032
RP CONTACTOR
:01
RP1
:02
RP2
:03
RP3
:04
RP contactor stuck closed
035
ESS INPUT
036
36GY19 GRID BLOWER FAILURE
:01
blower 1 stall
:02
blower 2 stall
:03
blower 1 open
:04
blower 2 open
:05
blower 1 & 2 delta too large
037
VOLTS 5 POS
038
VOLTS 15 POS
039
VOLTS 15 NEG
040
VOLTS 24 POS
041
VOLTS 24 NEG
DIRECTION SELECTED IN LOAD
042
BOX MODE
043
DRIVE SYSTEM BATTERY HI
044
DRIVE SYSTEM BATTERY LOW
045
CHOPPER 1 OPEN CIRCUIT
046
CHOPPER 1 FAILED
047
ENGINE STALL
E02014 3/01
TABLE II: DID PANEL FAULT CODES (Cont.)
EVENT
EVENT
RESTRICTION
No power
No power
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No power
No power
No power
No power
No power
No power
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
No propel
Electrical Propulsion System Components
DETECTION
INFORMATION
A panel connector B, C, or D is not
properly connected.
CN1 connector not properly
connected.
Auxiliary Blower System connector
not properly connected.
GF command and feedback don't
agree.
GFR command and feedback don't
agree.
RP command and feedback don't
agree.
RP command and feedback don't
agree.
RP command and feedback don't
agree.
RP command and feedback don't
agree.
RP command and feedback don't
agree.
Engine Speed Sensor out of range.
A grid blower has failed.
A grid blower has failed.
A grid blower has failed.
A grid blower has failed.
A grid blower has failed.
A grid blower has failed.
+5V Power Supply out of limits.
+15V Power Supply out of limits.
-15V Power Supply out of limits.
+24V Power Supply out of limits.
-24V Power Supply out of limits.
Selector switch moved to FORWARD
or REVERSE during self load.
Battery volts above limit.
Battery volts below limit.
An open circuit has occurred in
Chopper 1.
A failure has occurred in Chopper 1.
An engine stall condition has occurred.
Limp
Lockout
Possible
Limit
N/A
3
N/A
3
N/A
3
Yes (if
3
closed)
Yes (if
3
closed
N/A
3
Yes
3
Yes
3
E2-9