DESCRIPTION
NUMBER
115/215
INVERTER SYSTEM
:01
no direction
:02
for dir mismatch
:03
rev dir mismatch
:04
input volt low
:05
link volt low
:06
no hi spd data
:07
V line not ok
:08
I line not ok
:09
sys TIC fail
:10
DB GTO jn hot
:11
inv GTO jn hot
:12
VI test incomplete
116/216
INVERTER, PHASE A+/A-
:01
alarm A
:02
PTF A
:03
IGBT_SAT_AP
:04
IGBT_SAT_AN
117/217
INVERTER, PHASE A+
:01
alarm AP
:02
Aup fb not off
:03
phase A modl pos
:04
hold AP
:05
Aup fb not on
:06
Aup GTO not on
:07
IGBT_PS_AP
118/218
INVERTER, PHASE A+
:02
Aup temp short
:03
Aup temp open
:04
Aup temp warm
:05
Aup temp hot
:06
Aup fb not off S
E02014 3/01
TABLE III: DID PANEL FAULT CODES
(Codes Received From Inverter 1, 2)
EVENT
EVENT
RESTRICTION
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No power
No Propel
No Propel
No Propel
No Propel
No Propel
Electrical Propulsion System Components
DETECTION
INFORMATION
No direction called for
Calling forward, running backward
Calling reverse, running forward
Input voltage too low
Link filter voltage too low
No high speed data from system
controller
Line voltage not ok
Line current not ok
System TIC not being updated.
DB GTO juunction too hot
Inverter GTO junction too hot
VI test incomplete
Phase A GTO did not turn off
Overcurrent in phase A
IGBT saturated.
IGBT saturated.
Phase A pos GTO did not turn off
Phase A up feedback not off
Phase A positive module failed
Phase A positive and negative GTOs
on (positive turn on)
Phase A feedback not on
Phase A positive GTO did not turn on
IGBT protective shutoff
Phase A up thermistor short
Phase A up thermistor open
Phase A up thermistor warm
Phase A up thermistor hot
Phase A not off with enable/DC volts
Limp
Lockout
Possible
Limit
E2-19