SETUP & TESTING
HVAC INSTALLER SYSTEM SETTINGS TABLES

Thermostat System Settings Table

System setting
Description
Equipment Type
Note: Equipment Type related settings will return to
defaults if this is changed .
Control Setup
Used to lockout heating or cooling outputs . (Heat/Cool
mode only .)
Heat Pump Auxiliary Type
Selects auxiliary type . (Heat Pump mode only .)
Fan Control In Heating
Selects thermostat or equipment to control the fan in
heating . (Heat/Cool mode only .)
Number of Compressor Stages
Select number of compressor stages . (Heat Pump mode
only .)
Number of Auxiliary Heat Stages
Select number of auxiliary heat stages . (Heat Pump
mode only .)
Number of Stages of Heat
Select number of heat stages . (Heat/Cool mode only .)
Number of Stages of Cool
Select number of cool stages . (Heat/Cool mode only .)
Remote Temperature Sensor
Select if the remote sensor is attached, and uses backup,
Installed?
or is averaged with built-in .
Return Air Temperature Sensor
Select if return air temperature sensor is attached or not .
Installed?
Outdoor Temperature Sensor
Select if outdoor sensor is attached or not .
Installed?
Display Support Modules
Select if support module values are displayed on
Monitored Climate screen under Status .
Number of Controlling Support
Select number of sensors configured to be controlling
Modules Temp
temperature .
Number of Controlling Support
Select number of sensors configured to be controlling
Modules RH
RH .
Schedule
Enables or disables programmable schedule .
Progressive Recovery
Enables or disables progressive recovery .
Display Away Button?
Away allows the user to set the thermostat to a
predefined setpoint using a single button press .
The predefined setpoints can be selected in the User
Settings .
Display Heat Blast Button?
Select if the Heat Blast button is displayed .
Blast Offset
Amount of heating when Heat Blast is initiated .
12
(CONTINUED)
Factory default setting
(bold) and setting range
Heat/Cool
Heat Pump
Heat & Cool
Heat Only
Cool Only
Gas/Oil Heat
Electric Heat
Gas/Oil Heat
Electric Heat
One
Two
One
Two
One
Two
Three
One
Two
Three
No
Yes
Yes (fallback built-in)
Yes (average w/built-in)
No
Yes
No
Yes
Automation
No
Yes
0-8
0-4
Enabled
Disabled
Enabled
Disabled
No
Yes
No
Yes
3°F (1.5°C)
4°F (2°C)
5°F (2 .5°C)
SETUP & TESTING
HVAC INSTALLER SYSTEM SETTINGS TABLES
Thermostat System Settings Table (continued)
System setting
Description
Extended Fan – Heat
Extends fan operation after heat call ends .
Extended Fan – Cool
Extends fan operation after cool call ends .
Auto Changeover
Enable or disable Auto Changeover mode .
DeadBand
Auto Changeover mode deadband .
Auto Changeover Time
Minimum time between heating and cooling calls .
Internal Temperature Sensor
Field adjustment of controlling temperature sensors .
Offset
Internal RH% Sensor Offset
Field adjustment of internal RH sensor .
Equipment Minimum On Time
Minimum on time for heating and cooling .
Heating Minimum Off Time
Minimum off time for heating .
Compressor Minimum Off Time
Minimum off time for compressor protection .
Outdoor Temperature High
Enable or disable high balance point (Available if ODT
Balance Point
is installed .)
Select High Temperature Balance
If outside temperature is above the high balance point
Point
the aux heat operation is not allowed . (Available if high
balance point is enabled .)
Outdoor Temperature Low
Enable or disable low balance point (Available if ODT is
Balance Point
installed .)
Select Low Temperature Balance
If outside temperature is below the low balance point
Point
the compressor operation is not allowed . (Available if
low balance point is enabled .)
Stage Rate
Accumulation of equipment run time in staging
determination .
Factor
1 = more rapid staging of equipment (comfort),
5 = slower staging of equipment (economy) .
First Stage Differential
First stage differential .
Second Stage Differential
Second stage differential .
Third Stage Differential
Third stage differential .
Fourth Stage Differential
Fourth stage differential .
Service HVAC Reminder
The period for displaying the "HVAC Service reminder"
message .
Number of Months for Recurrence
Select number of months for displaying reminder .
(CONTINUED)
Factory default setting
(bold) and setting range
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
3°F (1.5°C)
2 to 9°F (1 to 4 .5°C)
4 Minutes
1 to 5 Minutes
0°F (0°C)
-4 to 4°F (-2 to +2°C)
0
-5 to 5
2 Minutes
1 to 5 Minutes
2 Minutes
1 to 5 Minutes
5 Minutes
1 to 5 Minutes
Enabled
Disabled
65°F (14.5°C)
0 to 80°F (-18 to 22°C)
Enabled
Disabled
20°F (-8°C)
0 to 60°F (-18 to 12°C)
Enabled
Disabled
2
1 to 5
1°F (0.5°C)
1 to 9°F (0 .5 to 4 .5°C)
1°F (0.5°C)
1 to 9°F (0 .5 to 4 .5°C)
1°F (0.5°C)
1 to 9°F (0 .5 to 4 .5°C)
1°F (0.5°C)
1 to 9°F (0 .5 to 4 .5°C)
Disabled
Enabled
12 Months
1 to 12 Months