15 mm
(0.591
"
)
2 mm
(0.079
")
0
-2 mm
(-0.079
")
1
-10 mm
(-0.394
")
0,08 m
(3.15
)
"
Fig. 40: Deviation SITRANS LG260 in rod version
1
Dead band (no measurement possible in this area)
L
Probe length
15 mm
(0.591
")
2 mm
(0.079
")
0
-2 mm
(-0.079
")
1
10 mm
(0.394
")
0,08 m
(3.15
")
Fig. 41: Deviation SITRANS LG260 in cable version in water
1
Dead band (no measurement possible in this area)
L
Probe length
Repeatability
Variables influencing measurement accuracy
Temperature drift - Digital output
Additional deviation through electromag-
netic interference acc. to EN 61326
Influence of the superimposed gas and pressure on measurement accuracy
The propagation speed of the radar impulses in gas or vapour above the medium is reduced by
high pressure. This effect depends on the superimposed gas or vapours.
PBD-51041059
0,3 m
(11.811
)
"
0,3 m
(11.811
")
≤ ±1 mm
±3 mm/10 K relating to the max. measuring range or
max. 10 mm (0.394 in)
< ±10 mm (< ±0.394 in)