5 Creating Measurement Scenes
• Matching character string
Logical operator
"|"
" "
"-"
Additional Information
Operator processing priority is (low) OR < AND <NOT (high).
Example: A|-B C (A OR NOT B AND C)
A|-B C
4
Click the OK.
The display will be below while setting the filter.
The mark displayed while
filter is being set.
Assigning variables
Assign defined variables to processing units. The method for assigning variables is the same for both
Scene variables and System variables.
1
Click Scene tab on the Edit flow screen to select a scene from the displayed list to edit.
2
Click Edit flow tab.
The Edit flow screen is displayed.
5 - 60
OR operator. "|" indicates a half-width vertical line or pipe line character.
Enter like A|B.
AND operator. " " indicates a half-width space character. Enter like A B.
NOT operator. "-" indicates a half-width minus character. Enter like –A.
When the filter is set, it becomes a light
blue background and the filter setting is
displayed.
FH/FHV Series Vision System User's Manual (Z365-E1)
Description
(1) –B Will be processed
(result will be X).
(2) A|X Will be processed
(result will be Y).
(3) Y C is processed.