Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp
BS1363 type they will not accept the plug connected to this
heater, therefore cut off the plug. When cut off this plug can
constitute a shock hazard if inserted into a socket outlet. It
must therefore be disposed of safely.
Before wiring the appropriate plug please note that the
wires in this mains lead are coloured in accordance with
the following code:
GREEN/YELLOW:
BLUE:
BROWN:
Connect the Green/Yellow wire to the terminal marked E
or the earth symbol or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured
Red.
Connect the Blue wire to the terminal marked N or coloured
Black. DO NOT connect the Brown (Live) or the Blue
(Neutral) wires to the Earth terminal of your 13 amp plug.
If the terminals of the plug are unmarked or you are in any
doubt, consult a qualified electrician.
Positioning the Heater
Select the position for the heater ensuring there is clearance
from any furniture and fittings of at least 300mm above the
heater and 150mm each side. The heater should only be
operated on a flat stable surface.
EARTH
NEUTRAL
LIVE
Operational modes
The electronic control has four control modes: AUTO,
MANUAL, BOOST and STANDBY mode (see Fig. 3)
In both MANUAL and AUTO mode there are three heat
settings options (see Fig. 4):
'Intelligent' Eco Mode - The product will automatically
regulate the room temperature accordingly. In this mode
the product operates at full power, however the output of
the product is automatically reduced and regulated as the
room temperature approaches the desired level. This mode
optimises energy use by calculating the most efficient and
effective way to achieve the desired temperature setting.
The desired room temperature can be adjusted at any time
during operation by pressing the appropriate key.
Low Heat - In this option, the appliance will operate at a low
heat setting, the appliance will automatically cycle at this
setting to maintain the room temperature setting.
High Heat - In this option, the appliance will operate at a
high heat setting, the appliance will automatically cycle at
this setting to maintain the room temperature setting.
Press the Mode key,' ', to toggle through the modes and
the ENTER key to confirm the mode selection. Note: when
selecting the mode if the ENTER key is not pressed, after
5 seconds the heater will activate the mode shown on the
LCD display.

Initial Operation

When the heater is initially connected to the mains the heater
will power up in MANUAL mode with a set temperature of
30˚C. The Mains and Heat indication neon will be lit and the
LCD display will be as per Fig.5. For subsequent operations
the unit will power up in its previous state, i.e. if it was in the
boost mode when the unit was plugged out when power is
reinstated it will resume in boost mode.
Setting the Time
To set the time press and hold ' ' for two seconds, the time
digits will begin flashing (see Fig. 6). Press the ' ' or ' '
buttons to set the time and press ENTER to confirm. The
heater will revert to the previous operational mode.
Standby Mode
With the heater ON, if the
will go into standby mode; the heater switches off, the
LCD will display the current set time, only the mains neon
remains illuminated. On pressing the
heater will come on in Manual mode and with a set point
setting of 25 ˚C.
button is pressed, the heater
button again the