10.2 Indoor Unit

10.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right is 4.
: For left side piping, piping connection for liquid should be about 5 from this line.
B
: For left side piping, piping connection for gas should be about 6 from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the left and right side of the installation plate. The meeting point of the extended line is
o
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side.
10.2.2 To Drill a Hole in the Wall and
Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
When the wall is hollow, please be sure to use the
sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Wall
More than 1
2 screw
241.5 mm
Measuring
Tape
128 mm
Model
MPS9***, MPS12***,
MPS15***
MPS18***, MPS24***,
MPS28***
CAUTION
Wall
More
than 2
128 mm
Installation
plate 1
Dimension
1
2
3
490 mm
82 mm
439 mm
432 mm
590 mm
82 mm
539 mm
532 mm
Indoor
Sleeve
for tube
assembly
ø70 mm through hole
34
Wall
More than 1
Indoor unit
241.5 mm
128 mm
4
5
6
93 mm
145 mm
219 mm
269 mm
Wall
Outdoor
15 mm
Bushing for tube
assembly
Putty or caulking compound
Approx. 5 - 7 mm