Figure 7: Connecting Through Network Hub Using PoE or Auxiliary Supply
Using an Auxiliary Power Supply
The IPSDC requires a 24 VDC nominal, 1 amp power supply with
battery backup. The IPSDC, readers, and other devices should be
referenced to the same ground.
For UL-listed installations, the auxiliary power supply must be an
approved UL294 power-limited supply, such as the Altronix Corp.
Model AL176ULX power supply. For UL of Canada (ULC)
installations, the auxiliary power supply must be listed to S319 or
S318.
1.
Mount the power supply near the IPSDC enclosure.
2.
Run the wire through the knockout hole to connector J8 (see
Figure
8). Pinouts include:
Pin 1 = +24 VDC
Pin 2 = – Ground (24 VDC return)
Note:
If the polarity is reversed, the fuse blows to prevent
damage. If the fuse blows, it automatically resets within
approximately five (5) seconds.
Figure 8: Auxiliary Power Supply Wiring
Note:
For UL-listed installations, Pin 3 is used for AC Power
Fail notifications; Pin 5 is used for Low Battery
notifications.
Callout
Description
1
+24 VDC from auxiliary power supply
2
Ground (0V) from auxiliary power supply
5
Callout
3
4
Configuring the IPSDC
After an IPSDC is installed, follow the instructions in the TruPortal
Software User Guide to use the browser-based Integrated
Configuration Tool (ICT) to:
Configure the IPSDC to recognize the IP address of the
System Controller (TP-SYS).
Change the IP address of the IPSDC.
Following is an overview of that procedure; see the TruPortal
Software User Guide or online help for details.
1.
Configure a local client workstation for static IP address
192.168.6.1 or a similar valid IP address (e.g., 192.168.6.x
where x is any number between 1 and 254 except 6).
2.
Make sure that the PC is not blocked from connecting to IP
address 192.168.6.6. (If the workstation normally connects to
the Internet via a proxy, the proxy settings in the browser may
need to be adjusted.)
3.
Open an Internet browser and go to http://192.168.6.6, the
default address of the IPSDC.
4.
Type the User ID and Password for the ICT.
The default values are install and install.
5.
On the Controller Parameters > Primary Network page,
configure the correct IP address for this IPSDC. A static IP
address is highly recommended. Make a note of the address
for your records. Click Save and then Apply.
6.
On the Controller Parameters > Panel Configuration page,
type the IP address of the System Controller. Click Save and
then Apply.
7.
Click Restart Application to commit the changes.
After a few minutes, the IPSDC will be accessible via the new
IP address and can be detected by the System Controller
when the [Scan for Hardware Changes] button is clicked in
the TruPortal User Interface.
8.
Repeat the procedure for each IPSDC.
Safe Shutdown Procedure
The following procedure can be performed in maintenance mode
or normal operation mode to turn off the IPSDC.
WARNING: Do not reset or restart the IPSDC in the middle of a
1.
Press SW6 and hold the button for three seconds until LEDs
D14 through D21 turn on and stay on. (See
Wire Color
locations of reset switches and LEDs.)
2.
Wait for about five seconds.
Red
3.
Remove power to the IPSDC or push SW5 to reset the
Black
IPSDC.
Description
Factory-wired chassis ground. Do not remove.
+24 VDC auxiliary power supply
firmware update or the IPSDC will become
nonfunctional. Refer to the TruPortal Software User
Guide for more information about firmware updates.
TruPortal IP-based Single Door Controller Quick Reference
Wire Color
Green
Figure 11
for

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Truportal tp-add-1dip-brd

Table of Contents