EVENT
NUMBER
DESCRIPTION
076
FB173 CARD
:01
speed FPGA DL
:02
speed FPGA run
:03
ALT FPGA DL
:04
Microcontroller
:05
slow task
:06
med task
:07
fast task
:08
FD task
:09
Alternator 3 phase volts bad
:10
alt FPGA timeout
077
INVERTER FAILED VI TEST
078
Inverter Background Communication Failure
084
CONTROL POWER SWITCH OFF
085
AUX COOLING
:02
aux rpmfb input
:03
aux rpm feedback
:04
abnormal shutdown
087
HP LOW
088
HP LIMIT
089
ENGINE SPEED DOES NOT MATCH
COMMAND
:02
RPM does not match command
091
INVERTER 1 CUTOUT
092
INVERTER 2 CUTOUT
094
ILLEGAL LIMP REQUEST
095
BAD BRAM BATTERY
096
UNEXPECTED PSC CPU RESET
098
DATA STORE
E02020 10/06
Table 2: DID PANEL FAULT CODES
(Codes Received from PSC)
EVENT
RESTRICTION
Electrical Propulsion System Components
EVENT
FB173 card failure
No power
No power
Inverter failed during test.
A failure in the inverter background communication was
Sys Event
detected.
SYS Event
Control power switch is turned off while truck is moving.
A fault has occurred in the auxiliary blower operation.
Rpm of Aux Blower out of range.
SYS Event
Rpm feedback does not match rpm command.
A fault occurred during shutdown
SYS Event
Horsepower adjust is at negative limit for 30 seconds.
SYS Event
Horsepower limit exceeded while in propulsion.
Engine speed feedback does not match commanded
SYS Event
speed.
SYS Event
SYS Event
SYS Event
A "limp mode" request is received while truck is moving.
SYS Event
BRAM battery voltage is low.
SYS Event
PSC CPU reset without request.
SYS Event
PTU data store command
DETECTION