Effective troubleshooting of RF communications sys-
tems can be complex and cannot always be reduced
to a simple check of electrical resistance. However, a
few basic troubleshooting procedures may be helpful
in identifying common problems. The following steps
can help identify a failed coaxial cable. Repair or
replace the cable if any of the following is true:
1. The center conductor is broken. There are more
than two ohms of resistance when measuring
from one end of the coaxial cable to the other.
2. The outer shield is broken.
3. There is an electrical connection between the
center conductor and the outer shield. There
are less than two megohms of resistance when
measuring from the center conductor to the
outer shield.
Fault Code
DBB0KK
DBB3KK
DBBRKR
DBB0KQ
DAW0KR
7P70Kr
7P70KR
9843KM
MFA0
D13004
Table 1: Fault History
Description
Source Voltage Error
Abnormality in VBAT Voltage (VHMS VBAT <10V)
Can-net System (J1939)
VHMS Connector Mismatch
IM Stopped Real Time Data
Too Much Payload Data For Requested Period
PLMIII Stopped Real Time Data
Truck Frame Number Changed
Manual Trigger
VHMS CHECK-OUT & TROUBLESHOOTING
FAULT CODES
Fault History
The fault history recorded in the VHMS controller can
help identify a failure within VHMS and in the com-
munications network to the engine, interface module
and PLMIII. The VHMS system provides the follow-
ing fault codes.
D13-15

Advertisement

Table of Contents
loading