Test I, Runs But Does Not Cool Properly - Norcold N10DCX Service Manual

Compressor refrigerators
Hide thumbs Also See for N10DCX:
Table of Contents

Advertisement

Troubleshooting Symptoms, cont'd.

Test I, Runs But Does Not Cool Properly

www.norcold.com
Check the temperature setting of
freezer and fresh food compartments.
Remove refrigerator from enclosure,
but keep DC power supply connected.
Inspect condenser coil for restriction.
YES
Is it
restricted?
NO
Check for 12 VDC at terminal (+) on
the control module.
YES
Is voltage
correct?
NO
Replace control module.
Remove restriction. Clean as needed.
Fan has failed. Replace refrigerator.