Test B, Fan Over Current Cut-Out - Norcold N10DCX Service Manual

Compressor refrigerators
Hide thumbs Also See for N10DCX:
Table of Contents

Advertisement

Troubleshooting Compressor Control Module, cont'd.

Test B, Fan Over Current Cut-Out

www.norcold.com
Remove refrigerator from enclosure,
but keep DC power supply connected.
With freezer and fresh food
compartments at temperature
setting "5", make sure that the
exterior cooling fan is operating.
YES
Is the fan
operating?
NO
Measure DC voltage at control
module terminal "+".
YES
VDC
10.4 - 15.4?
NO
Replace the refrigerator.
Fan has failed. Replace the fan.
Replace control module.
13
SERVICE MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents