WIRELESS CONTROLLER INSTALLATION

INSTALLING MULTIPLE WIRELESS CONTROLLERS

To install subsequent wireless water controllers repeat steps 3 to 8 for each additional wireless water
controller.
Once all wireless controllers are installed re-secure the transceiver access cover.

TROUBLE SHOOTING WIRELESS CONTROLLERS CHANNEL ASSIGNMENT

If at the end of the installation process screen
(C) is displayed do the following:
Confirm first that the power is still on at the
water heater.
If power is off turn it back on. If the channel has
been correctly assigned then the display should
show either screens (E), (F) or (G).
If screen (C) is still displayed un-install and reset the wireless controller and repeat the
installation procedure.
NOTE

UN-ASSIGNING AND RESETTING WIRELESS CONTROLLERS

1. Press the desired controller channel button
The LED will go out to signify that this channel is
now un-assigned.
2. Removing the batteries
controller will reset the wireless controller and
complete the un-install process.

INSTALLING WIRED AND WIRELESS CONTROLLERS

When installing combinations of both wired and wireless controllers, all wired
controllers MUST BE connected before the wireless controllers are assigned to a
IMPORTANT
transceiver channel.
Refer to page 1 to confirm the maximum number and combination of water controllers
that can be fitted
Wired water controllers can ONLY be added to an existing wireless installation when:
• All wireless transceiver channels have been un-assigned.
• All wireless controllers have been reset.
See "UN-ASSIGNING AND RESETTING WIRELESS WATER CONTROLLERS" above.
When the wireless transceiver is installed it automatically detects any wired
water controllers already connected to the water heater.
The LEDs of the channels assigned to wired controllers
The wired channels are assigned in sequence as follows:
MC70V or MC91 (programmed as a Master Controller) will be assigned to
Channel MC.
BC70V will be assigned to Channels No. 2 and/or No. 1.
MC91 (not programmed as a Master Controller) will be assigned to
Channels No. 2 and/or No.1 and/or No. 3.
Install the wireless controllers to any of the unassigned channels following
steps 1 to 9 on page 11.
Rinnai New Zealand
On / Off
(C)
.
c
from the wireless
d
12
Transfer
On / Off
Transfer
On / Off
(E)
c
No. 1
No. 2
No. 3
MC
e
will slow flash.
Transfer
On / Off
Transfer
(F)
(G)
d
Operation Manual