ELECTRICAL SYSTEM
Fuses 
Main Fuse Removal     
● Remove the seat (see Frame chapter) 
● Remove the fuse case cap [A] and take out the fuse [B]. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fuse Inspection 
● Inspect the fuse element.   
 If it is blown out, replace the fuse. Before replacing a blow fuse, 
always check the amperage in the affected circuit. If the 
amperage is equal to or greater than the fuse rating, check the 
wiring and related components for a short circuit. 
 
 
 
When  replacing  a  fuse,  be  sure  the  new  fuse  matches  the 
specified fuse  rating for  that  circuit.  Installation  of a  fuse  with  a 
 
higher rating may cause damage to wiring and components.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAUTION
【7-30】
 