Barco E192HSA User Manual
Barco E192HSA User Manual

Barco E192HSA User Manual

19-inch medical grade color display

Advertisement

Quick Links

E192HSA
User Guide
19-inch medical grade color display
K5902113 (451920611383)/01
27/11/2017

Advertisement

Table of Contents
loading

Summary of Contents for Barco E192HSA

  • Page 1 E192HSA User Guide 19-inch medical grade color display K5902113 (451920611383)/01 27/11/2017...
  • Page 2 Barco NV President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/en/support Visit us at the web: www.barco.com Printed in Italy...
  • Page 3: Table Of Contents

    5.3.8 Picture Swap.................... . 29 K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 4 Technical specifications ..................43 K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 5: Welcome

    1. WELCOME! About the product Overview The Medical Grade E192HSA is a color active matrix, liquid crystal display exclusively designed for med- ical imaging applications. The E192HSA is part of an LCD-display product line specifically designed for medical applications. Its wide number of features makes this product the ideal solution for Endoscopy and operating rooms.
  • Page 6 DVI cable • AC power cords • external power supply • 4 screws, 4 dented washers and an Allen key Keep your original packaging. It is designed for this display and is the ideal protection during transport. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 7: Parts, Controls And Connectors

    2. Multi-image selection key / Down key 3. Image zoom key / Up key 4. OSD Menu key / Enter key 5. Brightness decrease / Left key 6. Brightness increase / Right key 7. Power LED 8. Stand-by key K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 8: Rear View

    1. SDI in 2. SDI out 3. VGA in 4. Sync 5. CVBS in 6. CVBS out 7. S-Video out 8. RS232 9. Power on/off switch 10. Power in 11. DVI out 12. DVI in 13. R/Pr K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 9: Connector Pin Assignments

    4. Not connected 5. Not connected 6. SCL (for DDC) 7. SDA (for DDC) 8. Not connected 9. D1_Rx- (T.M.D.S.) 10. D1_Rx+ (T.M.D.S.) 11. GND (data 1 shield) 12. Not connected 13. Not connected 14. +5V output (*) K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 10: Rs232 Connector

    6. Not connected 7. Not connected 8. Not connected 9. Not connected 2.4.4 S-Video and S-Video-out connector Overview Image 2-7 1. Ground (Y) 2. Ground (C) 3. Luminance (Y) 4. Chroma (C) 5. SG: Shielded Ground K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 11: Vga Connector

    5. Not connected 6. Ground 7. Ground 8. Ground 9. Input power supply for DDC 10. Ground 11. Ground 12. SDA (for DDC option) 13. Horizontal sync in 14. Vertical sync in 15. SCL (for DDC option) K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 12 2. Parts, controls and connectors K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 13: Display Installation

    Interface connection About the interfaces The E192HSA can have multiple video inputs connected. Switching between the different inputs can be done easily with the Source shortkey ( ). The Picture in Picture (PiP) and Side-by-Side (SbS) functionality becomes available if more than one video source is connected.
  • Page 14: Power Supply Connection

    Power supply connection To connect the power supply 1. Connect the supplied external DC power supply unit to the +24 VDC power input of your E192HSA display. 2. Plug the other end of the power supply into a grounded power outlet by means of the proper power cord delivered in the packaging.
  • Page 15: Vesa Mount Installation

    Use an arm that is in compliance with VESA requirements. The monitor VESA interface has been designed for a safety factor 6 (to sup- AUTION port 6 times the monitor weight). In the medical system, use an arm with suitable safety factor (IEC60601–1). K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 16 3. Display installation K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 17: Daily Operation

    10 seconds. This will switch off the backlight and LCD and is indicated by a blinking orange power LED. To exit power save mode and switch the display back on, shortly press the key. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 18: Osd Menu Activation

    The OSD menu position and the time-out of the automatic close function can be adjusted in the OSD menu. Please refer to "OSD setting", page 30. OSD menu navigation OSD menu structure explained Below is an example of the OSD menu structure: K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 19: Shortkey Functions

    Shortkey functions About shortkey functions The concept of shortkey functions is to present a selection of commonly used functions immediately avail- able without the need to navigate through the OSD Menu. The different available shortkey functions are: K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 20: Main Source Selection

    1. Use the Image zoom key ( ) to select one of the available zoom factors. 4.6.4 Brightness adjustment To quickly adjust the brightness 1. While no OSD Menu is on the screen, press the Brightness decrease ( ) or Brightness increase ( ) keys to adjust the brightness as desired. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 21: Picture Swap

    To quickly swap the picture 1. While no OSD menu is on the screen, shortly press the Standby key ( ). The display will swap main and second input sources, depending on the current input source. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 22 4. Daily operation K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 23: Advanced Operation

    To adjust the brightness level 1. Bring up the OSD main menu. 2. Navigate to the Picture menu. 3. Enter the Brightness submenu. The command bar Brightness is highlighted. 4. Set the brightness level as desired and confirm. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 24: Contrast

    When color temperature 5600K, 6500K, 7600K or 9300K are selected only the white color point is adjusted. To select a color temperature preset 1. Bring up the OSD main menu. 2. Navigate to the Picture menu. 3. Enter the Color Temperature submenu. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 25: Gamma

    This command allows to add or subtract an offset to the input video signal (available only on video formats). To adjust the black level 1. Bring up the OSD main menu. 2. Navigate to the Picture advanced menu. 3. Enter the Black Level submenu. The command bar Black Level is highlighted. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 26: Smart Video

    When auto adjustment is activated, the phase and clock per line parameters are automatically adjusted. To activate auto adjustment 1. Bring up the OSD main menu. 2. Navigate to the Picture advanced menu. 3. Enter the Auto Adjustment submenu. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 27: Phase

    The command bar Clock/Line is highlighted. 4. Set the clock/line as desired and confirm. Display Format menu Overview • Main Source (Primary Source) • Component Mode • Zoom • Image Size • Picture Mode • Picture Source • Picture Position K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 28: Main Source (Primary Source)

    1. Bring up the OSD main menu. 2. Navigate to the Display Format menu. 3. Enter the Component Mode submenu. 4. Select one of the available component modes and confirm. 5.3.3 Zoom About zoom The available zoom factors for your display are: K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 29: Image Size

    S.b.S. Native: The 2 images are displayed with input pixel to LCD pixel mapping, with image crop if necessary • S.b.S. Fill: Both images scaled to fill half of the screen, with image crop if necessary K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 30: Nd Picture Source

    2. Navigate to the Display Format menu. 3. Enter the 2 Picture Source submenu. 4. Select one of the available 2 picture sources and confirm. 5.3.7 Picture Position About 2 picture positions The available 2 picture positions for your display are: K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 31: Picture Swap

    Hardware Version (main board identification) • Option SDI (SDI module identification) • Serial Number: ANxxxxxxxxxxxx To access information 1. Bring up the OSD main menu. 2. Navigate to the Configuration menu. 3. Enter the Information submenu. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 32: Language

    5. Set the OSD vertical position as desired and confirm. 5.4.3.3 OSD Time-out About OSD time-out The OSD menu can automatically close after a certain time of inactivity after the last selection was made. The available OSD time-out values for your display are: K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 33: Recall Profile

    User 3 To save a profile 1. Bring up the OSD main menu. 2. Navigate to the Configuration menu. 3. Enter the Save Profile submenu. 4. Select one of the available profiles to save and confirm. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 34: System Menu

    3. Enter the DVI output submenu. 4. Select one of the available options and confirm. 5.5.3 Keyboard lock About keyboard locking This setting allows you to disable the keyboard functionality and avoid unwanted access to the OSD func- tions. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 35: Power Saving

    2. By activating the OSD menu, see "OSD menu activation", page 16. To enable/disable power saving 1. Bring up the OSD main menu. 2. Navigate to the System menu. 3. Enter the Power Saving submenu. 4. Enable/Disable power saving as desired and confirm. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 36 5. Advanced operation K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 37: Important Information

    Provide as much distance as possible between the electrosurgical generator and other electronic equip- ment (such as monitors). An activated electrosurgical generator may cause interference with them. The interference can activate the OSD menu of the display and as such disrupt the functionality of the display. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 38 Do not cover or block any ventilation openings in the cover of the set. When installing the device in a cupboard or another enclosed location, heed the necessary space between the set and the sides of the cupboard. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 39 Safety and Essential Performance • CE c-UL-us, DEMKO, PSE (available on PSU), CCC • EMC Medical EMC Standards: IEC/EN 60601-1-2 (2007), EN55011/CISPR 11 (Class B), FCC CFR47 part 15 & 18 • RoHS-2, REACH, WEEE compliant K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 40: Environmental Information

    (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section "Limit Requirements of toxic substances in Electronic Information Products".
  • Page 41 “Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “Standard of Electronic Information Products Environmental Friendly Use Period”...
  • Page 42: Biological Hazard And Returns

    Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Canadian notice This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 43: Cleaning And Disinfection

    Indicates the device is approved according to the UL Recognition regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 44 Indicates the device serial number Indicates the device part number or catalogue number Warning: dangerous voltage Caution Consult the operating instructions 1. Values for xx and yy can be found in the technical specifications paragraph. K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 45: Legal Disclaimer

    Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
  • Page 46 SDI Compliance: SMPTE 425M (Level A), SMPTE 424M, SMPTE 292M, SMPTE 259M-C, SMPTE 296M, ITU-R BT.656, ITU-R BT.601 Remote control RS-232 (D-sub 9-pin) Power requirements External power supply: 100-240VAC, 50/60Hz, medical grade (nominal) Display power input: +24 VDC ±10% / 1.3 A K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 47 Storage altitude 12000m max. Timings DVI-VGA Item Name Pixel x Line Format Hor. Fr. Vert. Fr. Hor. Vert. (kHz) (Hz) Total Total 480i 720 x 487 15,734 59,94 NTSC 480p59 720 x 480 480p 31,47 59,94 K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 48 CVR1460 CVT1460 1400 x 1050 SXGA+ 65,32 59,98 (VESA) CVR1660D 1680 x 1050 WSXGA+1 64,67 59,88 CVT1660D 1680 x 1050 WSXGA+2 65,29 59,95 1920 x 1200 WUXGA1 74,038 59,95 2. OSD Smart Video set to “Diagnostic” K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 49 1920 x 1080 1080i 33,75 1080p29 1920 x 1080 1080p 33,72 29,97 1080p30 1920 x 1080 1080p 33,75 1080p50 1920 x 1080 1080p 56,25 1080p59 1920 x 1080 1080p 67,433 59,94 1080p60 1920 x 1080 1080p 67,5 K5902113 (451920611383) E192HSA 27/11/2017...
  • Page 50 6. Important information Dimensions 96.8 49.6 Image 6-2 K5902113 (451920611383) E192HSA 27/11/2017...

Table of Contents