Rheem 64DV Troubleshooting Manual page 50

For mid & high efficiency platforms. tankless gas
Hide thumbs Also See for 64DV:
Table of Contents

Advertisement

S V C 8 2 0 ( P ) P o c k e t M a n u a l P a g e
Test AC volts on
connector T
(Blue wire to Ground)
1 – 100 AC Volts
Cycle unit ON; while in
maintenance mode, check
flame rod status under table
0Y. IF flame rod(s) is
detecting flame, maintenance
mode will display: 05
Flame rod(s) test OK.
Remove and clean the
manifold assembly and
burner assembly (How to
Remove: Sections 4 & 5).
Reassemble and operate
unit again.
Did Error Code - 13 appear?
CHECK GAS SUPPLY,
VENTING, & GROUND.
Remove & reinsert T .
Operate unit again.
NO
IF code 13 appears:
Replace control board.
Clean flame rod(s). Operate
unit again. IF still does not
NO
detect flame:
Replace flame rod(s).
Unit is operating correctly.
Burner and/or manifold
needed to be cleaned.
CHECK the area around the
air intake for the possible
cause of dirty manifold and/
Indoor: 2 flame rods
White Molex – Grey Wire
Blue Molex – Blue Wire
49
or burner.
49