White Balance

White Balance has the following modes, all of which
can be set using VISCA Commands.
• Auto White Balance
This mode computes the white balance value output
using color information from the entire screen. It
outputs the proper value using the color temperature
radiating from a black subject based on a range of
values from 3000 to 7500K.
This mode is the factory setting.
• ATW
Auto Tracing White balance (2000 to 10000 K)
• Indoor
3200 K Base Mode
• Outdoor
5800 K Base Mode
• One Push WB
The One Push White Balance mode is a fixed white
balance mode that may be automatically readjusted
only at the request of the user (One Push Trigger),
assuming that a white subject, in correct lighting
conditions, and occupying more than 1/2 of the
image, is submitted to the camera.
One Push White Balance data is lost when the power
is turned off. If the power is turned off, reset One
Push White Balance.
• Manual WB
Manual control of R and B gain, 256 steps each

Automatic Exposure Mode

The variety of AE functions, which allow video signal
to output the optimum image for subjects from low
light condition, to high light conditions, is available.
• Full Auto
Auto Iris and Gain, Fixed Shutter Speed (NTSC: 1/60
sec., PAL: 1/50 sec.)
1)
• Shutter Priority
Variable Shutter Speed, Auto Iris and Gain
(1/1 to 1/10,000 sec., 16 high-speed shtter speeds plus
6 low-speed shutter speeds)
1) Flicker can be eliminated by setting shutter to
t1/100s for NTSC models used in countries with a 50 Hz
power supply frequency
t1/120s for PAL models used in countries with a 60 Hz
power supply frequency
• Iris Priority
Variable Iris (F1.6 to Close, 18 steps), Auto Gain and
Shutter speed
• Manual
Variable Shutter, Iris and Gain
• Bright
Variable Iris and Gain (Close to F1.6, 17 steps at
0 dB: F1.6, 15 steps from 0 to 28 dB)
AE – Shutter priority
The shutter speed can be set freely by the user to a
total of 22 steps – 16 high speeds and 6 low speeds.
When the slow shutter is set, the speed can be
1
1
1
1
1
/
s,
/
s,
/
s,
/
s,
/
s. The picture output is read at a
15
8
4
2
1
normal rate from the memory. The memory is updated
at a low rate from the CCD. AF capability is low.
In high speed mode, the shutter speed can be set up to
1/10,000s. The iris and gain are set automatically,
according to the brightness of the subject.
Data
NTSC (s)
15
1/10000
14
1/6000
13
1/4000
12
1/3000
11
1/2000
10
1/1500
0F
1/1000
0E
1/725
0D
1/500
0C
1/350
0B
1/250
0A
1/180
09
1/125
08
1/100
07
1/90
06
1/60
05
1/30
04
1/15
03
1/8
02
1/4
01
1/2
00
1/1
AE – Iris priority
The iris can be set freely by the user to 18 steps
between F1.6 and Close.
The gain and shutter speed are set automatically,
according to the brightness of the subject.
Data
Setting value
11
F1.6
10
F2
0F
F2.4
0E
F2.8
0D
F3.4
0C
F4
0B
F4.8
0A
F5.6
09
F6.8
Basic Functions
1
/
s,
30
PAL (s)
1/10000
1/6000
1/3500
1/2500
1/1750
1/1250
1/1000
1/600
1/425
1/300
1/215
1/150
1/120
1/100
1/75
1/50
1/25
1/12
1/6
1/3
1/2
1/1
Data
Setting value
08
F8
07
F9.6
06
F11
05
F14
04
F16
03
F19
02
F22
01
F28
00
CLOSE