2-2-9. White Balance Data Retrieving

. Subject:
Clear chart
. Measuring equipment: Vectorscope
. Specification:
None
1. Check that the luminescent spot stays near the center
of vectorscope, and then click the [3200K] button.
SNC_CM120
2. Put the color temperature correction filter C14 over the
lens.
3. Check that the luminescent spot stays near the center
of vectorscope, and then click the [5800K] button.
SNC_CM120
2-8
4. Check that "OK" is displayed in the upper right area of
the window, and then remove the color temperature
correction filter C14.
5. Click the [Next] button.
SNC_CM120
SNC-CS20/CM120