PROBLEM
1. No product is being
dispensed with draw valve
open and machine in the
"AUTO" mode.
2. The product is too stiff.
3. The product is too soft.
4. The mix in the mix hopper
is too cold.
5. The mix in the mix hopper
is too warm.
Models 358 & 359

Troubleshooting Guide

PROBABLE CAUSE
a. Beater motor is out on
reset.
b. Circuit breaker off or
blown fuse.
c. Inadequate mix in the mix
hopper.
d. Freeze-up in mix inlet
hole.
e. Beater is rotating
counterclockwise (from
operator end).
a. Inadequate mix in hopper.
b. Thermistor control is set
too cold.
a. Worn scraper blades.
b. Not enough air space is
around the unit.
c. Dirty condenser.
d. Out-of-date mix.
e. Thermistor control is set
too warm.
a. The temperature is out of
adjustment.
a. The mix hopper cover is
not in position.
b. Warm mix was placed in
the hopper.
c. The temperature is out of
adjustment.
23
REMEDY
a. Reset the freezer.
b. Turn breaker on or
replace fuse.
c. Fill the mix hopper with
mix.
d. Contact an authorized
service technician to
adjust the mix hopper
temperature.
e. Contact an authorized
service technician to
correct rotation to
clockwise.
a. Fill the hopper with mix.
b. Contact an authorized
service technician.
a. Replace regularly.
b. Allow for adequate air flow
across the condenser.
c. Clean monthly.
d. Use only fresh mix.
e. Contact an authorized
service technician.
a. Contact an authorized
service technician.
a. Place the hopper cover in
position.
b. Mix should be below 40_F
(4.4_C) when placed in
hopper.
c. Contact an authorized
service technician.
Troubleshooting Guide
PAGE
REF.
12
- -
17
- -
- -
17
- -
26
1
22
- -
- -
- -
18
21
- -