Cleaning; Disassembly; Brush Cleaning - Taylor 358 Operating Instructions Manual

Thick shake freezers
Hide thumbs Also See for 358:
Table of Contents

Advertisement

Cleaning

Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM
WATER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 2
Pour the cleaning solution into the mix hopper.
Figure 31
Step 3
While the solution is flowing into the freezing
cylinder, brush clean the mix hopper, the mix level
sensing probe and the mix inlet hole.
Step 4
Place the power switch in the "WASH" position. This
will cause the cleaning solution in the freezing
cylinder to be agitated.
Step 5
Place an empty pail beneath the door spout and
raise the draw handle. Draw off all the cleaning
solution. When the solution stops flowing from the
door spout, lower the draw handle and place the
power switch in the "OFF" position.
Repeat Steps 1 through 5 for the other side of the
freezer on the Model 359.
Models 358 & 359

Disassembly

MAKE SURE THE POWER SWITCH IS IN
THE "OFF" POSITION. Failure to do so may cause
injury from hazardous moving parts or electrocution.
Step 1
Remove the freezer door, beater, scraper blades,
and the drive shaft from the freezing cylinder. Take
them to the sink for cleaning.
Repeat for the other side of the freezer on the
Model 359.
Step 2
Remove the front drip tray and the splash shield.

Brush Cleaning

Step 1
Prepare a sink with an approved cleaning solution
(example: Kay-5R or Stera-SheenR). USE WARM
WATER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS
IMPORTANT: Follow label directions, as too
STRONG of a solution can cause parts damage,
while too MILD of a solution will not provide
adequate cleaning. Make sure all brushes provided
with the freezer are available for brush cleaning.
Step 2
Remove the seal(s) from the drive shaft(s).
Step 3
Remove the scraper blade clips from the scraper
blades.
Step 4
From the freezer door(s) remove:
S
gasket(s)
S
front bearing(s)
S
draw valve(s)
Remove all o-rings.
Note: To remove o-rings, use a single service towel
to grasp the o-ring. Apply pressure in an upward
direction until the o-ring pops out of its groove. With
the other hand, push the top of the o-ring forward. It
will roll out of the groove and can be easily removed.
If there is more than one o-ring to be removed,
always remove the rear o-ring first. This will allow
the o-ring to slide over the forward rings without
falling into the open grooves.
19
Operating Procedures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

359

Table of Contents