Endress+Hauser gammapilot FTG 671 Technical Information

Non-invasive, radiometric limit detection intrinsically safe signal circuit [eex ib] iic/atex ii (2) gdf or scintillation or geiger-müller detector
Hide thumbs Also See for gammapilot FTG 671:

Advertisement

Technical
Information
TI 177F/00/en
Radiometric Level Measurement
gammapilot FTG 671
Non-invasive, radiometric limit detection
Intrinsically safe signal circuit [EEx ib] IIC /
ATEX II (2) GD
For scintillation or Geiger-Müller detector
Application
The Gammapilot FTG 671 transmitter is
designed for
• non-invasive, level limit detection
in containers - mixers, reactors,
hoppers, silos, tanks - with inflammable,
abrasive, poisonous and aggressive
bulk material and liquids, e.g. in acid
tanks, boilers, cement silos, ballast
hoppers, cyclones, cupolas, rotary
furnaces etc.. Thanks to the fact that the
measuring system is fitted externally, it
also finds application in the food
processing industry.
Gammapilot transmitters may also be
used for applications in explosion
hazardous areas, and possess
intrinsically-safe sensor circuits
conforming to EEx ib IIC, or EEx d IIC,
EEx de IIC depending on the detector.
Endress
The Power of Know How
The Gammapilot
FTG 671 transmitter is a
19" plug-in card, shown
here in Monorack II
housing
Features and Benefits
• Suitable for scintillation detector
DG 57 or Geiger-Müller counters
DG 17 or DG 27
• Uses lowest possible source activity
with DG 57/100 mm or longer
• Digital signal transmission
- Interference-free function with
two-core installation cable up to
1000 m
• Intrinsically safe sensor circuits
- Ex-protection withoutZener barriers
approved as overspill protection
(VBF, WHG Germany) and for use
in explosion hazardous areas
• Simple operation with parameter
matrix
- Uniform handling as for all
Commutec transmitters
• Practical background functions
- Automatic compensation of source
decay
- Automatic adjustment of switch
point
• Commutec transmitter
- Simple connection to automatic
systems via Rackbus
- Up- and download of data
+
Hauser

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser gammapilot FTG 671

  • Page 1 DG 17 or DG 27 • Uses lowest possible source activity Application with DG 57/100 mm or longer • Digital signal transmission The Gammapilot FTG 671 transmitter is designed for - Interference-free function with two-core installation cable up to • non-invasive, level limit detection 1000 m •...
  • Page 2: Measuring System

    Scintillation Counter DG 57 Output Signals Most measurement systems use the DG The Gammapilot FTG 671 has two limit 57 scintillation counter, thus ensuring: relays which can be operated with freely • highest sensitivity adjustable hysteresis independently of •...
  • Page 3: Measurement Principle

    Background Functions The maximum and minimum countrates The Gammapilot FTG 671 is equipped and N are obtained when the with a number of background functions transmitter is calibrated, whereby their...
  • Page 4: Operation

    Configuration at Front Panel Operational Status Gammapilot FTG 671 transmitters can The operational status of the transmitter be configured at the front panel. is indicated by means of six LEDs which can be clearly seen from a distance.
  • Page 5: Remote Control

    Three possibilities exist: Modbus, Profibus or FIP. Process Control Systems • Gateways and operating programs are Gammapilot FTG 671 transmitters are easily integrated into supervisory control available for a variety of fieldbuses, systems. programmable logic controllers (PLC), process control systems (PCS) and •...
  • Page 6: Installation

    Installation Racksyst plug-in cards must be installed outside explosive hazardous areas in a rack or protective housing. Endress+Hauser can provide the following alternatives: • 19" rack (84 HP wide) for mounting up to 12 transmitters in the control room • Half 19" wide field housing with...
  • Page 7: Technical Data

    Electrical Connection Technical Data • Power supply: 24 V DC (+6 V…-4 V); - residual ripple 2 V, within tolerance • Supply current: max. 135 mA • Power consumption: max. 3.3 W at 24 V, max. 4.0 W at 30 V •...
  • Page 8: Product Structure

    Product Structure Gammapilot FTG 671 Certificate F [EEx ib] IIC*/ATEX II (2) G Approval for use as overspill protection (Germany) Version A Single measurement point FTG 671- product designation EEx d ib IIC, EEx de IIC, EEx d IIC are determined by the DG 57 detector...