7. EMI Measurement for LX16-family

Spectrum analyzer
0.1-1000MHz
IEEE
Workstation
Figure 10: Measuring setup
PLL
CKSCR
16 MHz
0xBB
12 MHz
0xBA
8 MHz
0xB9
4 MHz
0xB8
2 MHz
0xDC
Table 1: CKSC- settings for several PLL frequencies
Port
Function
port x0
output
port x1
output
port x2
output
port x3
input
port x4
output
port x5
output
port x6
output
port x7
input
Table 2: I/O port settings for toggle test
Probe
Pin
GND
GND
GND1
DVSS
GND2
VSS
GND3
AVSS
Table 3: Ground measurement with 1ohm probe
Schirmbox
RS232
Remarks
default after reset
PLL disabled
I/O-State
high
low
2 kHz toggling
-
high
low
2 kHz toggling
-
Remarks
common ground
oscillator/ext. bus
I/O-ground
analog ground
Vdd
10Ai
Vss
10Ai
X-TEM
Ferrit
Filter
+
Power supply
5V
-
Filter
11