Robot-Mounted Equipment Grounding; Installing User-Supplied Safety Equipment - Omron Cobra 350 CR/ESD User Manual

Table of Contents

Advertisement

5.12  Installing User-Supplied Safety Equipment

Robot-Mounted Equipment Grounding

The Cobra 350 Joint 3 quill and tool flange are not reliably grounded to the robot base. If haz-
ardous voltages are present at any user-supplied robot-mounted tooling, you must install a
ground connection from that tooling to the ground point on the robot base. Hazardous
voltages can be considered anything in excess of 30 VAC (42.4 VAC peak) or 60 VDC.
Also, see Tool Flange Dimensions for Cobra 350 Robots (Units in mm) on page 122 for the
grounding point on the tool flange.

5.12 Installing User-Supplied Safety Equipment

The user is responsible for installing safety barriers to protect personnel from coming in con-
tact with the robot unintentionally. Depending on the design of the workcell, safety gates, light
curtains, and emergency stop devices can be used to create a safe environment. Read the Robot
Safety Guide for a discussion of safety issues.
76
2
XSYSTEM
DC
IN
24V
3
Figure 5-15. Earth Ground Location
Table 5-16. Earth Ground Location Description
Item
1
Robot Interface Panel
2
Ground Label
3
Ground Screw
WARNING: ELECTROCUTION RISK
Failing to ground robot-mounted equipment or tooling that uses hazardous
voltages could lead to injury or death of a person touching the end-effector
when an electrical fault condition exists.
1
ENET
ENET
GND
AC
Servo
1
200 -
240V
Description
Cobra 350 User's Guide
05624-000 Rev. K