8. maintenance guide

8.4.4 Gas Valve

Tools
Remove the two screws under the boiler and disconnect the
gas pipe on the left of the gas valve
1
58
Remove the gas valve
TIME
15 min
2
Legend:
1 - Gas valve
2 - Solenoids
3 - Throttle adjustment
4 - Offset adjustment
5 - Inlet test nipple