2. INTRODUCTION
GENERAL
The Rx100 telemetry interface is designed to allow control of a variety of integrated dome cameras using BBV's
range of up-the-coax telemetry transmitters. See appendix A for a complete list of supported domes.
The Rx100 interface is supplied in an IP67 rated enclosure. It will be necessary to make suitable holes in the
enclosure to permit cable entry and exit. Adequately rated cable glands and or flexible conduit should be used at
all times to avoid compromising the protection afforded by the enclosure as supplied. Any holes made in the
enclosure for any other purpose should be sealed with a non-hardening waterproof sealant, taking care to ensure
that the internal electronics are not contaminated.

Rx100 TECHNICAL SPECIFICATION

Power Requirements:
Current Consumption:
Features:
Engineering Facilities:
Telemetry Signals:
Telemetry signals either:
• up-the-coax (max distances, 250M of RG59 or 500M of CT125/RG11).
• or twisted pair 0-20mA current loop.
Video Input:
1v p-p 75Ω terminated input via BNC socket.
Video Output:
1v p-p to 4v p-p 75Ω impedance via BNC socket.
Up to 16 full-scene preset positions can be stored within the interface depending upon the model of dome.
Dimensions (external):
RX100/WBX
Width: 190 mm Width: 190mm
Length: 280 mm Length: 380mm
Height: 130 mm Height: 130mm
Weight:
1.0Kg
Temperature range:
-10° Celsius to +40° Celsius
Rx100 installation manual V1.17 29 Aug 08.doc
RX100 9-12V ac/dc – plug mounted PSU provided
RX100/24 – 24Vac or 230Vac
RX100 - 100mA @ 12Vdc maximum
RX100/24 – 630mA @ 230Vac maximum
• Serial data output 2 wire RS485/RS422.
• 4 alarm inputs.
• 1 N/C alarm output.
• Up to 16 pre-set positions can be stored within the Rx100.
• Relay capable of switching 1Kw of lighting.
• Unit auto-tunes to the coaxial telemetry signal.
• LED readout for continual system status.
• Video launch amplifier provided with Gain and Lift controls.
• Colour-coded cage clamp terminals. Mains terminal connections:
Live, Neutral and Earth and Low Voltage.
RX100/24/WBX
3.6Kg