BBV RX100 Installation Manual page 38

Sony dome interface receiver installation guide
Hide thumbs Also See for BBV RX100:
Table of Contents

Advertisement

Appendix B - Trouble shooting guide.
Symptom: No video from interface.
Possible causes:
Camera is not powered or not connected to 'CAMERA' BNC on interface.
Check power and cabling.
Interface is not powered.
Check power.
Video out not connected to 'TELEMETRY' BNC on interface.
Check cabling.
If the after following the above check list video still not present then remove both BNCs from the interface
and connect together using a female/female barrel connector to check video path from camera to control
point.
Symptom: No camera control but lights relay operates with LIGHTS key on transmitter.
Possible causes:
Dome data cable is not connected correctly.
Check cabling, most commonly due to data cables swapped.
Dome configuration switches if fitted not set correctly.
Check configuration.
Symptom: No camera control and lights relay not operating.
Possible causes:
Interface not seeing Telemetry signal.
Check that telemetry is present on video cable using either oscilloscope or adjust v.hold on monitor to
view frame blanking period and check for black/white band. If missing, power down/up the transmitter.
Should this fail, swap video between working and non-working channels.
Earth loops can interrupt telemetry operation if sufficiently severe.
If hum bars are apparent, fit isolation transformer to coaxial cable.
Check cable and error LEDs on interface.
See SETUP section earlier in this manual for correct indication.
If the problem persists having followed the above steps, technical assistance can be received from
Building Block Video. Tel: +44 (0)1323 444600
Rx100 installation manual V1.17 29 Aug 08.doc
Page 38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents