BBV RX100 Installation Manual

Sony dome interface receiver installation guide
Hide thumbs Also See for BBV RX100:

Advertisement

RX100
Dome Interface Receiver
Installation
Guide
Building Block Video Ltd.,
17 Apex Park,
Diplocks Industrial Estate,
Hailsham, East Sussex, BN27 3JU UK.
Tel: +44(0)1323 842727
Fax: +44(0)1323 842728
Support: +44(0)1323 444600
www.bbvcctv.com

Advertisement

Table of Contents
loading

Summary of Contents for BBV BBV RX100

  • Page 1 RX100 Dome Interface Receiver Installation Guide Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU UK. Tel: +44(0)1323 842727 Fax: +44(0)1323 842728 Support: +44(0)1323 444600 www.bbvcctv.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Pre-installation Checks and Safety Procedures Unpacking Important safety precautions 2. Introduction General Rx100 Technical specification Transmitter compatibility chart Cable connection method Fig. 1 Wago cable connectors Cable types 3. Installation Operating voltage Rx100 connections Fig. 2 Rx100 pcb connections 4.
  • Page 3: Pre-Installation Checks And Safety Procedures

    1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES UNPACKING Check Packaging - Upon taking delivery of the unit, inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Check Contents - Upon taking delivery of the unit, unpack the unit carefully and check that all the items are present and correct.
  • Page 4 Damage Requiring Service - Servicing by qualified personnel should be carried out under the following conditions: When the power-supply cord or plug is damaged. If liquid has been spilled or objects have fallen into the unit If the internal electronics of the unit have been exposed to rain or water If the unit does not operate normally by following the operating instructions.
  • Page 5: Rx100 Technical Specification

    2. INTRODUCTION GENERAL The Rx100 telemetry interface is designed to allow control of a variety of integrated dome cameras using BBV’s range of up-the-coax telemetry transmitters. See appendix A for a complete list of supported domes. The Rx100 interface is supplied in an IP67 rated enclosure. It will be necessary to make suitable holes in the enclosure to permit cable entry and exit.
  • Page 6: Transmitter Compatibility Chart

    TRANSMITTER COMPATABILITY CHART Tx300 Tx400 Variable Speeds Speeds Speed Fixed Speed Zoom Focus Iris Pre-sets Patrols Lights Autopan Camera Functions Rx100 installation manual V1.17 29 Aug 08.doc Tx400DC Tx1000 Tx1000DC Proportional Proportional Speeds Joystick Joystick Tx1500 Proportional Joystick Page 6...
  • Page 7: Cable Connection Method

    CABLE CONNECTION METHOD Fig. 1: cage clamp connectors CABLING RECOMMENDATIONS FOR THE Rx100 INTERFACE. Although BBV do not specify any particular type, manufacturer or supplier of cables, the following ESD Electronic Services (01279 626777) cables have been used successfully for production and testing: ESD Part Number: Description: 0222586G...
  • Page 8: Operating Voltage

    3. INSTALLATION OPERATING VOLTAGE The Rx100 requires all connections to the PCB to be made by the installer, and via terminal blocks or by plug and socket. These connections are: power in, video in, video out, and serial data to dome. In addition connections for alarm in, alarm out and lights if required are provided.
  • Page 9: Diagnostic Aids

    4. SETUP DIAGNOSTIC AIDS Two red LEDs and one Green LED are mounted on-board to give simple system status information. Their functions are as follows: Cable LED Regular Blinking Blinking but mainly ON Blinking but mainly OFF Error LED Both LEDs Data LED (Iss PCB 4 onwards only) Test Link All BBV equipment is designed to auto-tune and compensate for any discrepancies in the transmitted telemetry...
  • Page 10 Panasonic WV-CSR400 Panasonic WV-CSR600 Panasonic WV-CSR650 Panasonic WV-CS850 Pelco SD5 'Spectra' *Philips G3 (RS232) Sanyo VCC9200P Sensormatic Speed dome Sony EVI-31D Star MD100 & MD200 VCL TP domes *Vicon Surveyor 2000 Videcon dome Vista PowerDome *Rx100/24 230Vac powered with 24Vac 100VA output.
  • Page 11 Fig.5 SYSTEM SCHEMATIC SHOWING INTEGRATION OF DOME INTO Tx1000 SYSTEM. Rx200 Rx100 static camera with lights/ dome camera static camera wash/wipe 4 local alarms STATIC alarm cable LENS B B V 1000 PROGRAM AUTOPAN IRIS FOCUS CAMERA SELECT PATROL PRESET MONITOR B B V LENS...
  • Page 12 Panasonic WV-CSR400, WV-CSR600. WV-CSR650 Panasonic WV-CS850 Pelco Spectra dome & Esprit head (P protocol) Philips AutoDome (RS232/485) Samsung SCC-641 Sanyo VCC-9200P Sensormatic speeddome (RS422 Only) Sony EVI-D31, 1000 Star MD-800, MD-1200S, MD-1200H, MD-2000 Ultrak KD6 VCL-TP Vicon Surveyor Videcon Dome Videcon VCP451 Camara Vista PowerDome Rx100 installation manual V1.17 29 Aug 08.doc...
  • Page 13 BBV Rx100/24 Supply Additional information The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be at mains voltages.
  • Page 14: Application Notes

    BBV Rx100 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out. 16 Full scene presets. 2 preset patrols. Slow preset tour. Started by pressing AUTOPAN (As patrol 1 but slow speed movement and 10 second dwell) 5 minute datum/park driving to preset 1 or slow preset tour.
  • Page 15 BBV Rx100 Addendum to manual for the following domes: Borsatec BT2790FF Dome Rx100 software RX1_B3V2 Application Notes The RX100 provides the following functionality when controlling the above mentioned dome: Variable speed Pan/Tilt. 16 Full scene presets. 2 RX100 preset patrols.
  • Page 16 BBV Rx 100 Addendum to manual for the following domes: Dennard type 2050/2055/2060 dome. Rx100 software RX1_D2V12 Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus 16 full scene presets (additional presets can be programmed using dome's menu) 2 preset patrols 4 alarm inputs driving to preset 1 - 4 or dome sequence 001 - 004, link selectable Advanced Features Tx400DC Dome User Menu...
  • Page 17 BBV Rx 100 Addendum to manual for the following dome: Dynacolor 7720 COAXIAL TELEMETRY ONLY NOT 20mA Rx100 software RX1_D4V7 Application Notes Variable speed Pan/Tilt (single function at a time, pan or tilt or zoom or focus) Zoom/Focus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 –...
  • Page 18 Early dome - Set dome address to 1: 8 way switch 1 ON, 2-7 OFF. 4 way switch 1-3 ON, 4 OFF. Later dome – Dome ID switch: 1 ON, 2-8 OFF. Duplex/Simplex switch:1-2 OFF. Dynacolor protocol S2:1-4 OFF, S1:1-3 ON BBV Rx 100 Addendum to manual for the following domes: Forward Vision protocol...
  • Page 19 BBV Rx 100 Addendum to manual for the following dome: JVC TK-C655B/676/675B combination cameras Rx100 software RX1_J2V4 Application Notes The RX 100 provides the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Autofocus can be enabled/disabled from the dome menu. 16 Full scene presets.
  • Page 20 BBV Rx100 Addendum to manual for the following domes: Kalatel Cyberdome (Firmware 1/1/02 or later) Rx100 software RX1_K1V2 Application Notes Variable speed Pan/Tilt. Zoom/Focus/Iris 16 Full scene presets. 2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 03) Shadow TOUR 1 playback using AUTOPAN key.
  • Page 21 BBV Rx 100 Addendum to manual for the following dome: Merit Li-Lin PIH-717X/7000/7600/7625 series Rx100 software RX1_L1V8 Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4 Advanced Features Tx400 Tx1000 Toggle Menu display...
  • Page 22 BBV Rx 100 Addendum to manual for the following domes: Mark Mercer 150 and D250/500 series Rx100 software RX1_M1V6 Application Notes Variable speed Pan/Tilt. Zoom/Focus override, Iris override 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.
  • Page 23 BBV Rx 100 Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus, Iris Open/Close 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4. Autopan Advanced Features Tx400 Tx1000 Entry/Exit Dome Menu ‘#’ 1 SET (select menu item) ‘#’...
  • Page 24 BBV Rx 100 Addendum to manual for the following domes: Panasonic WV-CS850 / 860 Rx100 software RX1_P1V10 Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus, Iris Open/Close (Hold for auto-iris) 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 Autopan/Patrol learn-play using autopan key Advanced Features Tx400...
  • Page 25 BBV Rx 100 Addendum to manual for the following dome: Pelco Spectra (P-mode RS485 protocol) Rx100 software RX1_P2V10 Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4 Dome Pattern definition and playback Advanced Features Tx1000...
  • Page 26 BBV Rx 100 Addendum to manual for the following dome: Philips AutoDome including G3A and G3B (RS232 control only, not Bi-Phase compatible) Rx100 software RX1_P3V11 Application Notes Variable speed Pan/Tilt.. Zoom/Focus, Autofocus. 16 full scene presets. 2 preset patrols. 4 alarm inputs driving to preset 1 – 4. Dome AutoPlay record &...
  • Page 27 Using the advanced features when using a BBV Tx400DC Menu Access : Press and HOLD # and tap 1 TWICE will display the dome’s menu Use the joystick to navigate the cursor. FOCUS FAR or FOCUS NEAR can be pressed to enter the next menu item or to return press either IRIS OPEN or IRIS CLOSE.
  • Page 28 BBV Rx100 & Rx100/24 Addendum to manual for the following domes: Samsung SCC-641 Interface Rx100 software RX1_S5V3 Application Notes The Rx100 allows control of the following dome features: Variable speed Pan/Tilt, Zoom/Focus/Iris, 16 full scene presets, 2 preset patrols, 4 alarm inputs driving to preset 1 – 4, Dome Pattern 1 playback using the AUTOPAN key ,Menu Access...
  • Page 29 BBV Rx 100 Addendum to manual for the following domes: Sensormatic Speeddome Rx100 software RX1_S3V6 Coaxial telemetry ONLY. Not twisted pair! Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus, Iris Open/Close 7 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 Pattern 1 define –...
  • Page 30 Reset dome to default RS232 control of dome 9600 Baud, No parity, 8 data bits, 1 stop bit. The camera uses a sub-miniature 8 pin DIN socket. A Sony supplied VISCA to DB9 RS232 cable may help with installation. Connection details:...
  • Page 31 Rx 100 Interface Receiver Addendum to manual for the following domes: Chugai SMD-08II, SMD-12, SMD-12II, SMD-20 Sanyo VCC-9200P Star MD-800, MD-1200S, MD-1200H, MD-2000 Rx100 software RX1_S2V6 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt, from 0.8deg/sec to 120deg/sec.
  • Page 32 BBV Rx100 Addendum to manual for the following dome: Diamond/Ultrak KD6 Dome Rx100 software RX1_D1V5 up-the-coax telemetry only. Not twisted pair Application Notes Variable speed Pan/Tilt. Zoom/Focus, Iris override, Auto exposure ON/OFF 16 Full scene presets. 2 preset patrols. 4 alarm inputs driving to preset 1 - 4.
  • Page 33 BBV Rx 100 Addendum to manual for the following domes: VCL TP protocol Microsphere/Orbiter range. Rx100 software RX1_V1V10 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Autofocus following a Zoom In/Out. 16 Full scene presets.
  • Page 34 BBV Rx 100 Application Notes The RX 100 provide the following functionality when controlling the above dome. Variable speed Pan/Tilt. Zoom/Focus, Autofocus with manual override. 16 full scene presets (additional presets available using dome's menu) 2 preset patrols 4 alarm inputs driving to preset 1 - 4. Additional commands: RUN TOUR 80.
  • Page 35 BBV Rx100 Addendum to manual for the following domes: Videcon Dome Rx100 software RX1_V4V2 Application Notes The RX 100 provide the following functionality when controlling the above mentioned dome Variable speed Pan/Tilt. 16 Full scene presets. 2 RX100 preset patrols.
  • Page 36 BBV Rx100 Addendum to manual for the following camera: Application Notes The RX 100 provides control of Zoom and Focus and Menu Access. Advanced Features Tx400 Tx1000 Display MENU ‘#’ 1 '#' WASH The camera and Rx100 are linked using RS485 for control and video for the camera signal.
  • Page 37 BBV Rx100 Application Notes The RX 100 provide the following functionality when controlling the above mentioned dome Variable speed Pan/Tilt. Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out. 16 Full scene presets. 2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 02) Learned tour playback using AUTOPAN key.
  • Page 38 Appendix B - Trouble shooting guide. Symptom: No video from interface. Possible causes: Camera is not powered or not connected to ‘CAMERA’ BNC on interface. Check power and cabling. Interface is not powered. Check power. Video out not connected to ‘TELEMETRY’ BNC on interface. Check cabling.
  • Page 39 --- Blank for your notes --- Rx100 installation manual V1.17 29 Aug 08.doc Page 39...
  • Page 40: Product Description

    Other BBV products. Product Description TX300 TX400 TX400DC TX1000 MK2 TX1500 FBM range RX100 RX200 RX300 RX400P RX45X (AC) RX55X (DC) Multi RS485 protocol and BBV up-the-coax telemetry receivers RX450/550 STARCARD STARCARD/CONVERTER ACCESSORIES Rx100 installation manual V1.17 29 Aug 08.doc Single camera desktop telemetry transmitter with BBV up-the-coax &...

Table of Contents