BBV Rx 100
Addendum to manual for the following domes:
Mark Mercer 150 and D250/500 series
Rx100 software RX1_M1V6
Application Notes
Variable speed Pan/Tilt.
Zoom/Focus override, Iris override
16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 – 4
2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.
Advanced Features
Tx400
Pan 'U'-turn (180deg flip)
'#' 1
Dome Reset
'#' 4
A slow preset patrol can be started by pressing AUTOPAN. The preset dwell is fixed at 20 seconds with a dome speed of 1.
RS485 control of dome using the following connections:
Rx100
Description
J3-C1
TX/RX-
J3-C2
TX/RX+
Notes:
The alarm output relay opens for approx 5 seconds upon power up and following a local alarm activation.
Links
Function
J6/1-2
Enable 2 minute inactivity datum mode if the link is fitted.
J6/3,4,5
Select datum operation, J6/4-5 = goto preset 1, J6/3-4 = start slow preset patrol.
Only operational whilst the dome is not running a patrol.
Rx100 installation manual V1.17 29 Aug 08.doc
Interface Receiver
Tx1000
Tx1500 DM Mux/DS/DSL/DS2/BX2 etc
'#' WASH
1 '#'
*889 002 or *889 10 10 2
'#' LIGHTS
4 '#'
*889 005 or *889 10 10 5
Dome
6 pin connector
RS485 B Pin 4 (RED)
RS485 A Pin 3 (GREEN)