Generac Power Systems PM-DCP Owner's Manual
Generac Power Systems PM-DCP Owner's Manual

Generac Power Systems PM-DCP Owner's Manual

20-light remote annunciator

Advertisement

Remote Annunciator
GEN.
RUN.
LOW
OIL
PRESSURE
GENERAC
Surface Mount Models:
004996-0
004998-0
PM-DCP 20-light
O w n e r 's M a n u a l
BATTERY
LOW
HIGH
CHARGER
BATTERY
BATTERY
FAILURE
VOLTAGE
VOLTAGE
PRE - ALARMS
HIGH
LOW
LOW
WATER
FUEL
WATER
TEMP.
TEMP.
®
POWER SYSTEMS
1 AMP
Flush Mount Models:
004997-0
004999-0
RPM
OVER
OVER
SENSOR
CRANK
SPEED
LOSS
LOW
HIGH
EMERGENCY
WATER TEMP
OIL
STOP
LOW WATER
PRESSURE
LEVEL
POWER MONITOR
RESET
RE-ARM
ALARM
HORN
Standard Annunciator
Annunciator w/Remote Relay Panel
GEN.
SYSTEM
COMMS.
POWER
READY
OK
NOT
LINE
IN
POWER
AUTO
TEST
REMOTE START
ON
ON
OFF
OFF
0A6733

Advertisement

Table of Contents
loading

Summary of Contents for Generac Power Systems PM-DCP

  • Page 1 PM-DCP 20-light Remote Annunciator O w n e r ’s M a n u a l GEN. BATTERY HIGH OVER OVER GEN. SYSTEM COMMS. RUN. CHARGER BATTERY BATTERY SENSOR CRANK SPEED POWER READY FAILURE VOLTAGE VOLTAGE LOSS PRE - ALARMS...
  • Page 2: Table Of Contents

    20-light Remote Annunciator Detailed Specifications ..........2 System Ready..............5 Environmental Specifications ........2 Communication OK ............6 Power Supply Requirements..........2 Audible Annunciator ............6 Communication With Generator Control System ..2 Test Switch ..............6 Interface With Other Equipment ........2 Re-Arm Horn Switch ............6 Agency Compliance ............2 Reset Switch ..............6 Transportation and Storage ..........2 Relay Output ..............6...
  • Page 3: Packaging And Mounting

    20-light Remote Annunciator The Remote Annunciator panels (Models 004996-0, and PACKAGING AND MOUNTING 004998-0) are mounted using any combination of the Enclosure type Sheet metal box. mounting holes in the back panel of the box itself. Base panel Generac part #0A6985/0A7437 Surface Mount Dimensions Front panel Generac part #0A6988/0A7443...
  • Page 4: Setting To Passive Mode

    20-light Remote Annunciator An annunciator connected to a system controller would The ‘Re-Arm Horn' switch can be used to turn off and be a slave. re-arm the horn, or the alarms can be fully acknowl- edged using the ‘Reset' switch. Annunciator Connected to System Controller The ‘Reset' switch will turn off and re-arm the horn, and any flashing lights will switch to the ON state until the...
  • Page 5: Generator Power

    20-light Remote Annunciator GENERATOR POWER BATTERY CHARGER AC FAILURE This light indicates different things depending on the This light annunciates upon loss of 120 VAC power sup- type of system it is attached to. ply to the battery charger. This requires an AC relay with normally closed contacts connected in the circuit •...
  • Page 6: Communication Ok

    20-light Remote Annunciator COMMUNICATION OK RELAY OUTPUT This LED will be on as long as there is proper commu- The RAP will also provide a pair of Normally Open con- nication between the Remote Annunciator Panel and the tacts which will mimic the status of the Audible alarm generator control system.
  • Page 7: Troubleshooting

    20-light Remote Annunciator TROUBLESHOOTING GUIDE No LEDs are lit. 1. Check for proper battery supply at J1 pins 3 and 4. • J1 pin 3 should be + Battery (12 or 24 volts). • J1 pin 4 should be – Battery. •...
  • Page 8: Notes

    20-light Remote Annunciator Generac ® Power Systems, Inc.
  • Page 9: Electrical Data

    20-light Remote Annunciator Wiring Diagram - Drawing No. 0E5616 Generac ® Power Systems, Inc.
  • Page 10 20-light Remote Annunciator Wiring Diagram - Drawing No. 0E5617 10 Generac ® Power Systems, Inc.
  • Page 11 20-light Remote Annunciator Wiring Diagram - Drawing No. 0E5617 Generac ® Power Systems, Inc. 11...
  • Page 12: Exploded Views & Parts Lists

    20-light Remote Annunciator Assembly - Drawing No. 0F0169 ITEM PART NO. QTY. DESCRIPTION 0A6985 PANEL ANNUNCIATOR REAR 0A6388D ASSY, 20LT MODBUS ANNUN G-PNL 040213 PCB SUPPORT SNAP-IN 1/4" 0A6990 SUPPORT, PC BOARD 036901 SCREW PPHM #6-32 X 3/8 0A6988 PANEL ANNUNCIATOR FRONT 0A6733 DECAL ANNUNCIATOR PANEL 061284...
  • Page 13 20-light Remote Annunciator Assembly - Drawing No. 0F0173 [ OTHER SIDE OF PANEL ] VIEW A - A VIEW B - B ITEM PART NO. QTY. DESCRIPTION 0A7437 PANEL ANNUNCIATOR REAR 0A6388D ASSY, 20LT MODBUS ANNUN G-PNL 040213 PCB SUPPORT SNAP-IN 1/4" 0A6990 SUPPORT, PC BOARD 036901...
  • Page 14 20-light Remote Annunciator Assembly - Drawing No. 0F0175 REM O TE RELAY PANEL WIRIN G 2 0 LI G H T ITEM PART NO. QTY. DESCRIPTION 0A6985 PANEL ANNUNCIATOR REAR 0A6388D ASSY, 20LT MODBUS ANNUN G-PNL 0A9036B 8CH REM RLY PNL MODBUS RRP G-P 040213 PCB SUPPORT SNAP-IN 1/4"...
  • Page 15 20-light Remote Annunciator Assembly - Drawing No. 0F0177 [ OTHER SIDE OF PANEL ] 11 12 VIEW A - A VIEW B - B ITEM PART NO. QTY. DESCRIPTION 0A7437 PANEL ANNUNCIATOR REAR 0A6388D ASSY, 20LT MODBUS ANNUN G-PNL 0A9036B 8CH REM RLY PNL MODBUS RRP G-P 040213 PCB SUPPORT SNAP-IN 1/4"...
  • Page 16 ® GENERAC POWER SYSTEMS, INC. P.O. BOX 8 • WAUKESHA, WI 53187 PH: (414) 544-4811 • FA X: (414) 544-4851 Part No. 0F0270 Revision 0 (03/29/04) Printed in U.S.A.

Table of Contents