Parts and their functions (continued)
10.
RS‑422 connector <RS‑422>
This RS-422 connector (RJ-45) is connected when exercising serial
control over the unit from an external device. Use a cable with the
following specifications for the connection to this connector.
Furthermore, by shorting the R-TALLY signal (2-pin) with the GND
(1-pin), it is possible to light the tally lamp (red) in the camera head
section of the unit.
<NOTE>
• Do not connect PoE cable to the RS-422 port.
• Do not apply a voltage to the R_TALLY_IN signal pin.
• Menu settings enable the output to pin 7 and pin 8 of the red tally
and green tally signals received by the unit. Output is by contact
output, and normally is "OPEN", then it becomes "MAKE" for output.
(→ page 60)
LAN cable
(category 5e or above, straight cable),
1
*
max. 1000 m (3280 ft)
*
1
Use of an STP (shielded twisted pair) cable is recommended.
Pin
No.
1
2
3
4
„ Example OPTION_OUT1, OPTION_OUT2 connector
connections
AW-UE150
OPTION_OUT1
OPTION_OUT2
GND
Pin
Signal
Signal
No.
GND
5
TXD+
R_TALLY_IN
6
RXD+
RXD–
7
OPTION_OUT1
TXD–
8
OPTION_OUT2
Voltage: Maximum DC12 V
Current: Maximum 100 mA
11.
Service switches <SERVICE>
Perform switch settings before turning the unit on.
LAN
LINK
ACT
RS-422
12 V
IN
IR ID
AUDIO IN
Function
SW1
Switches for initialization
(Refer to the explanations in "Initialization 1"
and "Initialization 2")
SW2
Always leave at OFF (used for factory
SW3
adjustments)
SW4
Initialization 1
• Reset the user authentication settings and host authentication
settings for network connection.
(This will delete all the registered user information (IDs/passwords)
and host information (IP addresses).)
• With the IR ID switches and service switches set as shown below,
turn on the power of the unit.
<NOTE>
• When initialization is complete, the status display lamp on the front
of the unit blinks green. Restart the unit to confirm the initialization.
Initialization 2
• The unit is reset to the state it was in at the time of purchase. (All
camera menu setting values and network setting values are reset.)
• With the IR ID switches and service switches set as shown below,
turn on the power of the unit.
<NOTE>
• When initialization is complete, the status display lamp on the front
of the unit blinks green. Restart the unit to confirm the initialization.
12.
HDMI connector <HDMI>
This is the HDMI video output connector.
13.
3G SDI OUT connector <3G SDI OUT>
This is the 3G SDI video signal output connector.
16
SERVICE
3G SDI OUT
G/L IN
OPTICAL
MONI OUT 12G SDI OUT
Service switches
Factory settings
SW1
SW2 SW3 SW4
ON
OFF
SW1
SW2 SW3 SW4
ON
OFF
OFF
OFF
OFF
OFF

Hide quick links: