technical bulletin
Appendix
Main Control Board Setting For XJAM CDU (Software Version 300-0043-06 V1.0)
Model Name
Control Board
Default Setting
ZX15KCE-TF5
ZX15KCE-PFV
ZX21KCE-TF5
ZX21KCE-PFV
ZX30KCE-TF5
ZX30KCE-PFV
ZX38KCE-TF5
ZX38KCE-PFV
ZX45KCE-TF5
Table 4 - Settings for XJAM CDU
Main Control Board Setting For XJAL CDU (Software Version 300-0043-05 V1.0)
Model Name
Control Board
Default Setting
ZXI06KCE-TF5
ZXI06KCE-PFV
ZXI09KCE-TF5
ZXI11KCE-PFV
ZXI14KCE-TF5
ZXI14KCE-PFV
ZXI15KCE-TF5
ZXI16KCE-PFV
ZXI18KCE-TF5
Table 5 - Settings for XJAL CDU
Document Part # 026-4909 Rev 1 20-OCT-2011
Visit our website at http://www.emersonclimate.com/ for the latest technical documentation and updates.
The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein
or their use or applicability. Computer Process Controls, Inc. reserves the right to modify the designs or specifications of such products at anytime without notice. Computer Process Controls, Inc. does not assume responsibility
for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Computer Process Controls, Inc. product remains solely withthe purchaser and end-user.
026-4909 20-OCT-20111 Emerson is a trademark of Emerson Electric Co. ©2011 Computer Process Controls, Inc. All rights reserved. Printed in the USA.
Installation Instructions: XJ Scroll Condenser to E2
Rotary Switch 2bit Dip-Switch
0
ON/ON
1
ON/ON
2
ON/ON
3
ON/ON
4
OFF/OFF
5
ON/ON
6
OFF/OFF
7
OFF/OFF
8
OFF/OFF
9
OFF/OFF
Rotary Switch 2bit Dip-Switch
0
ON/ON
1
ON/ON
2
ON/ON
3
ON/ON
4
OFF/OFF
5
OFF/OFF
6
ON/ON
7
OFF/OFF
8
OFF/OFF
9
OFF/OFF
This document may be photocopied for personal use.
3bit Dip-Switch
Bit 1: To set evaporator fan control mode
- "OFF": Evaporator Fan On/Off Logic Same
As Compressor
- "ON": Evaporator fan will be ON all the time
no mater whether compressor is ON/OFF or
defrosting
Bit 2: To set defrost mode
- "OFF": Using Emerson defrost module
- "ON": Using customer defrost module
Bit 3: Not used yet.
3bit Dip-Switch
Bit 1: To set evaporator fan control mode
- "OFF": Evaporator Fan On/Off Logic Same
As Compressor
- "ON": Evaporator fan will be ON all the time
no mater whether compressor is ON/OFF or
defrosting
Bit 2: To set defrost mode
- "OFF": Using Emerson defrost module
- "ON": Using customer defrost module
Bit 3: Not used yet.
Page 13 of 13