Troubleshooting Guide; Section 8 Troubleshooting Guide - Taylor Freezemaster 300 Series Operating Instructions Manual

Table of Contents

Advertisement

Section 8
PROBLEM
1. No product is being
dispensed with draw valve
open and the machine in
the "AUTO" mode.
2. The product is too stiff.
3. The product is too soft.
4. The mix in the mix hopper
is too cold.
Models 336, 338 & 339

Troubleshooting Guide

PROBABLE CAUSE
a. Freeze--up in mix inlet
hole.
b. Beater motor out on reset.
c. The beater is rotating
counterclockwise from the
operator end.
d. The circuit breaker is off
or the fuse is blown.
e. There is inadequate mix in
the mix hopper.
f. The air orifice is not
installed.
g. Air tube is installed in the
"STANDBY" position.
a. The viscosity needs
adjustment.
b. The air orifice is not
installed.
a. Viscosity needs
adjustment.
b. Not enough air space
around unit. (Air cooled
units)
c. Worn scraper blades.
d. Dirty condenser (A/C)
e. Mix is out of date.
f. Loss of water. (W/C)
g. Loss of refrigerant.
a. The temperature is out of
adjustment.
27
REMEDY
a. Call service technician to
adjust the mix hopper
temperature.
b. Reset the freezer.
c. Contact service technician
to correct rotation to
clockwise from operator
end.
d. Turn the breaker on, or
replace the fuse.
e. Fill the mix hopper with
mix.
f. Install air orifice in air
tube.
g. Install the air tube in the
"AUTO" position.
a. Contact service
technician.
b. Install air orifice in air
tube.
a. Contact service
technician.
b. Allow for adequate air flow
across the condenser.
c. Replace regularly.
d. Clean monthly.
e. Use only fresh mix.
f. Locate cause of water
loss and correct.
g. Call a service technician.
a. Call service technician to
adjust the mix hopper
temperature.
Troubleshooting Guide
PAGE
REF.
------
14
------
------
22
21
21
------
21
------
6
30
25
------
26
------
------

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freezemaster 338Freezemaster 336Freezemaster 339