Wire The 9-Wire Remote-Mount Transmitter To The Sensor - Emerson Micro Motion 4200 Installation Manual

2-wire transmitter
Hide thumbs Also See for Micro Motion 4200:
Table of Contents

Advertisement

Mounting and sensor wiring
April 2019
2.3
Wire the 9-wire remote-mount transmitter to
the sensor
Prerequisites
Prepare 9-wire cable as described in the sensor documentation.
Connect the cable to the sensor-mounted junction box as described in the sensor
documentation. You can access all product documentation on the documentation
DVD shipped with the product or at www.emerson.com/flowmeasurement.
Procedure
1. Remove the transmitter-to-sensor wiring compartment cover to reveal the terminal
14
Figure 2-4: Attaching and securing transmitter to mounting bracket
Tip
To ensure the mounting bracket holes are aligned, insert all attachment bolts into
place before tightening.
connections.