Installing system components
3.5 Connecting the Mobile Panel
Replacing the connecting cable and closing the terminal compartment
1. Remove the RJ45 plug from the X1 port.
2. Remove the connector from the X80 port.
3. Remove the connecting cable.
4. Position the replacement cable so that the terminal compartment cover fits exactly over
the terminal compartment.
5. Position the end of the connecting cable in the guide.
6. Plug the connector into port X80. Note the mechanical coding on the connector.
7. Plug in the RJ45 connector at port X1. Make sure that the connector audibly engages.
8. Place the terminal compartment cover over the terminal compartment. Tighten the
corresponding screws using a torque of 0.2 Nm.
Note
• When closing the terminal compartment cover, make sure that the corresponding seal
• Make sure that the cables in the terminal compartment are not bent too much.
• When closing the terminal compartment cover, be careful not to trap the cables.
9. All Mobile Panels 2nd Generation with the exception of the KTP400F Mobile: Attach the
retainer.
See also
Connecting the Mobile Panel connecting cable (Page 53)
56
is undamaged and properly seated. Otherwise the specified degrees of protection
cannot be guaranteed.