The device name must be unique and satisfy the DNS conventions within the local
network. These include:
– Restriction to 127 characters (letters, digits, hyphen or point)
– A name component within the device name, for example, a string between two points,
– Special characters such as umlauts, brackets, underscores, slashes, spaces, etc. are
– The device name must not start or end with the "-" character.
– The device name must not take the form n.n.n.n (n = 0 to 999).
– The device name must not start with the character string "port-xyz-" (x, y, z = 0 to 9).
4. Confirm your entries.
The dialog closes.
5. Restart the HMI device, see section "Restarting the HMI device (Page 101)".
5.11

Enabling NTP

To obtain the time of the HMI device from a time server, you can specify up to four different
time servers. The time is synchronized using the "Network Time Protocol". The
synchronization cycle applies to all configured time servers.
Requirement
● The HMI device and time server are located in the same network.
● The Control Panel is open.
Mobile Panels 2nd Generation
Operating Instructions, 09/2018, A5E33876626-AC
may not exceed 63 characters.
not permitted.
Parameterizing the Mobile Panel
5.11 Enabling NTP
127