Operation; Specifications - Sony CMA-D2MDCE Instructions For Use Manual

Camera adaptor
Hide thumbs Also See for CMA-D2MDCE:
Table of Contents

Advertisement

Operation

POWER switch
Set the POWER switch to ON.
The unit supplies DC power to the connected
camera via the CAMERA connector.
The unit outputs video camera signals and
inputs sync signal depending on the camera
and the camera cable being used.
For detailed information, refer to the
operating instructions of the video camera.
18
Operation / Specifications

Specifications

General
Power requirements:
100 to 240 V AC (-), 50/60 Hz
DC output
13 V DC (
Peak inrush current
(1) Power ON, current probe
method: 25 A (240 V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1:
8 A (230 V)
Operating temperature
0°C to +40°C (32°F to 104°F)
Storage temperature
–20°C to 60°C (–4°F to 140°F)
Operating humidity
20% to 80%
(no condensation allowed)
Storage humidity
20% to 90%
(no condensation allowed)
Operating pressure
700 hPa to 1,060 hPa
Storage and transport pressure
700 hPa to 1,060 hPa
Dimensions
210 × 44 × 200 mm (w/h/d)
3
(8
/
× 1
8
excluding projecting parts
Mass
1.1 kg (2 lb 7 oz)
Protection against electric shock:
Class 1
Protection against harmful ingress of water:
Ordinary
Degree of safety in the presence of flammable
anesthetics or oxygen:
Not suitable for use in the presence
of flammable anesthetics or
oxygen
Mode of operation:
Continuous
Input/Output Connectors
Input connector
GENLOCK IN (BNC type)
Output connectors
VIDEO OUT (BNC type) (1)
S VIDEO (4-pin mini DIN) (1)
CAMERA (4-pin) (1)
Input/output connector
CAMERA (12-pin) (1)
), 1.3A
3
7
/
× 7
/
inches)
4
8

Advertisement

Table of Contents
loading

Table of Contents