Dometic RM 8 Series Service Manual page 34

Absortion refrigerator for leisure vehicles
Hide thumbs Also See for RM 8 Series:
Table of Contents

Advertisement

COMPONENTS
Electronics
POWER MODULE
X 105
X 114
Fuse 1A
RF Module for RMCD
(250V)
remote control
X105 = 12 V Supply / - Wiring
Recognition of heating element
X114 = Reed switch or alt. electr. lock
X108 = Temperature sensor (NTC)
X110 = Connection to burner control device (+/-, failure)
X111 = alt. 2. electr. Locks or reed switch
TD S34
AES
X 108
X 110
X 111
J4 / J5
X 106
X 109
Connection to
Display
X106 = D+/Solar
X109 = Interior light
J4/J5 = Frame heating
J1 = +12 V IN for heating element
J2 = +12 V Heating element
X102 = Heating element mains power
X101 = Mains power inlet
Contacts
J1/ J2
X 102
X 101
Beeper

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents