Dimension drawings

9.5 Hazardous Locations XPP-5

9.5
Hazardous Locations XPP-5
Dimensions in mm (inch)
2 conductor shielded cable
¾" NPT
Nameplate
171.5 (6.75) nominal
Mounting flange
Locknut
2" NSPL
Probe body (potted aluminum housing)
Probe body (potted aluminum junction box)
● C.S.A Approved for:
– Class I, Div. 1, Groups A, B, C, and D
– Class II, Div. 1, Groups E, F, and G
– Class III
● Aluminum body with die-cast flange and zinc-plated locknut.
● Pre-amp and cable potted in the probe's body.
64
SITRANS WM300 MFA
Operating Instructions, 08/2018, A5E45090709-AA