Configuring View Options

Use the following CLI syntax to configure view options:
CLI Syntax: config>system>security>snmp
The following displays a view configuration example:
*A:cses-A13>config>system>security>snmp# info
----------------------------------------------
----------------------------------------------
*A:cses-A13>config>system>security>snmp#
Page 260
view view-name subtree oid-value
mask mask-value [type {included|excluded}]
view "testview" subtree "1"
mask ff
exit
view "testview" subtree "1.3.6.1.2"
mask ff type excluded
exit
community "uTdc9j48PBRkxn5DcSjchk" hash2 rwa version both
community "Lla.RtAyRW2" hash2 r version v2c
community "r0a159kIOfg" hash2 r version both