Facility Alarm List; Table 45: Alarm, Alarm Name/Raising Event, Sample Details String And Clearing Event - Alcatel-Lucent 7950 SR System Management Manual

Hide thumbs Also See for 7950 SR:
Table of Contents

Advertisement

Facility Alarm List

The following table(s) show the supported Facility Alarms.

Table 45: Alarm, Alarm Name/Raising Event, Sample Details String and Clearing Event

Alarm *1
Alarm Name/Raising Event
7-2001-1
tmnxEqCardFailure
7-2003-1
tmnxEqCardRemoved
7-2004-1
tmnxEqWrongCard
7-2005-1
tmnxEnvTempTooHigh
7-2006-1
tmnxEqFanFailure
7-2007-1
tmnxEqPowerSupplyFailureOvt
7-2008-1
tmnxEqPowerSupplyFailureAc
7-2009-1
tmnxEqPowerSupplyFailureDc
7-2011-1
tmnxEqPowerSupplyRemoved
7-2017-1
tmnxEqSyncIfTimingHoldover
7-2019-1
tmnxEqSyncIfTimingRef1Alarm
with attribute
tmnxSyncIfTimingNotifyAlarm ==
'los(1)'
7-2019-2
tmnxEqSyncIfTimingRef1Alarm with
attribute
tmnxSyncIfTimingNotifyAlarm ==
'oof(2)'
7-2019-3
tmnxEqSyncIfTimingRef1Alarm with
attribute
tmnxSyncIfTimingNotifyAlarm ==
'oopir(3)'
7-2021-x
same as 7-2019-x but for ref2
7-2030-x
same as 7-2019-x but for the BITS
input
7-2033-1
tmnxChassisUpgradeInProgress
7950 SR OS System Management Guide
Sample Details String
Class MDA Module: failed, reason:
Mda 1 failed startup tests
Class CPM Module: removed
Class IOM Module: wrong type
inserted
Chassis 1: temperature too high
Fan 2 failed
Power supply 2 over temperature
Power supply 1 AC failure
Power supply 2 DC failure
Power supply 1, power lost
Synchronous Timing interface in
holdover state
Synchronous Timing interface, alarm
los on reference 1
Synchronous Timing interface, alarm
oof on reference 1
Synchronous Timing interface, alarm
oopir on reference 1
same as 7-2019-x but for ref2
same as 7-2019-x but for the BITS
input
Class CPM Module: software
upgrade in progress
Facility Alarms
Clearing Event
tmnxChassisNotification
Clear
tmnxEqCardInserted
tmnxChassisNotification
Clear
tmnxChassisNotification
Clear
tmnxChassisNotification
Clear
tmnxChassisNotification
Clear
tmnxChassisNotification
Clear
tmnxChassisNotification
Clear
tmnxEqPowerSupplyInser
ted
tmnxEqSyncIfTimingHol
doverClear
tmnxEqSyncIfTimingRef
1AlarmClear
same as 7-2019-1
same as 7-2019-1
same as 7-2019-x but for
ref2
same as 7-2019-x but for
the BITS input
tmnxChassisUpgradeCom
plete
Page 447