Management Access Filter Commands
If the cfm-opcode match condition is configured then a check must be made to see if the Ethertype is
either IEEE802.1ag or Y1731. If the Ethertype does not match then the packet is not CFM and no
match to the cfm-opcode is attempted.
The CFM (ieee802.1ag or Y1731) opcode can be assigned as a range with a start and an end number
or with a (less than lt, greater than gt, or equal to eq) operator.
If no range with a start and an end or operator (lt, gt, eq) followed by an opcode with the value
between 0 and 255 is defined then the command is invalid.

Table 7: Opcode Values

Page 128
The following table provides opcode values.
CFM PDU or Organization
Reserved for IEEE 802.1 0
Continuity Check Message
Loopback Reply
Loopback Message
Linktrace Reply
Linktrace Message
Reserved for IEEE 802.1
Reserved for ITU
Reserved for ITU
Reserved for ITU
Reserved for ITU
Reserved for ITU
Reserved for ITU
Reserved for ITU
Reserved for IEEE 802.1 0
Acronym
CCM
LBR
LBM
LTR
LTM
AIS
LCK
TST
APS
MCC
LMR
LMM
1DM
DMR
DMM
7950 SR OS System Management Guide
ConfIgurable Numeric
Value (Range)
0
1
2
3
4
5
6 – 31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48 – 63
64 - 255