2. Details of Menu Items in Adjustment Settings for Operators
0614 [Exit Guide Close Timing]
Set the timing to close the Paper Exit Guide. The proper timing for the paper in use prevents the
deflection of the staple bundle at the time of ejection.
[Setting]
0615 [Output Trail Edge Press Setting]
Set whether or not to hold the trailing edge of sheets when ejected on the Shift Tray. Setting it [ON]
reduces the diversion of sheets due to the paper type and paper condition.
[Setting]
0616 [Output Fan Setting]
Set the fan operation to the sheets on the shift tray. Air blowing peels off the sheets in close contact.
[Setting]
0617 [Output Fan Level]
Adjust the fan volume to the sheets on the shift tray. Increase the air level if the sheets are in close
contact.