Introduction
Thank you for purchasing TOSVERT VF-MB1 series Inverter.
Before using CANopen
and correctly utilize its excellent performance.
After reading this function manual, please keep it handy for future reference.
For details of its general handling, see an instruction manual attached with the option unit.
・TOSVERT VF-MB1 Instruction Manual ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ E6581697
・TOSVERT VF-MB1 Communications Function Instruction Manual ・・・・・・・・・・・ E6581726
®
* CANopen
and CiA are a registered trademark of CAN in Automation.
Handling in general
Do not connect or disconnect a network cable while the Inverter power is on.
It may lead to electric shocks or fire.
See the instruction manual attached with the option unit for cautions the handling.
Mandatory
Otherwise, it may lead to electric shocks, fire, injuries or damage to product.
Network control
Do not send the value out of the valid range to network variables.
Otherwise, the motor may suddenly start/stop and that may result in injuries.
Prohibited
Use an additional safety device with your system to prevent a serious accident due to the
network malfunctions. Usage without an additional safety device may cause an accident.
Mandatory
Set up "Communication error trip function (see below)" to stop the Inverter when the
network is deactivated by an unusual event such as tripping, an operating error, power
outage, failure, etc.
- Communication error trip time, Operation at communication error
(Refer to "6.4 Communication disconnection detection function" for details)
Mandatory
Deactivated the Inverter may cause an accident, if the "Communication error trip
function" is not properly set up.
Make sure that the operation signals are STOP before resetting Inverter's fault. The
motor may suddenly start and that may result in injuries.
Notes on operation
When the control power is shut off by the instantaneous power failure, communication
will be unavailable for a while.
The Life of EEPROM is approximately 100,000 times. Avoid writing a command more
than 100,000 times to the same parameter of the Inverter and the communication board.
®