Periodical Recording Tab - Setting The Periodical Recording Mode - Sony IPELA SNC-RX550N User Manual

Sony user guide network camera ipela series
Hide thumbs Also See for IPELA SNC-RX550N:
Table of Contents

Advertisement

Image file name
Type the file name you want to assign to the images to
be recorded. You can use up to 10 alphanumeric
characters, - (hyphen) and _ (underscore) for naming.
Suffix
Select a suffix to be added to the file name.
Date & time: The Date & time suffix is added to the
image file name.
The Date & time suffix consists of lower two-digits
of the year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits)
and consecutive number (2 digits), thus adding a 14-
digit number to the image file name.
Sequence number: A consecutive number of 10 digits
between 0000000001 and 4294967295 and an
consecutive 2 digits number is added to the image
file name.
Tip
A consecutive number added to Date & time and
Sequence number is used to identify each of the
multiple files created with one alarm event.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the alarm to be linked with the recording of image
and audio files.
Sensor input 1: The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2: The external sensor that is connected to
sensor input 2 of the camera I/O port.
Object detection: The alarm by the object detection
function.
Click Detection, and the Object detection menu is
displayed to allow you to set the object detection
function (page 65).
Note
In the case that the synchronized preset position is
specified in Position at alarm in the Preset position
menu, the alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period during which
alarm detection is effective.
Click Schedule and the setting menu for the effective
period is displayed. ("Setting the Schedule —
Schedule Menu" on page 63)
Alarm buffer
Select Use alarm buffer when you record the image/
audio of before and after alarm detection (pre-alarm,
post-alarm).
If you do not select the alarm buffer, only the image at
the moment of the alarm detection is recorded.
Click Alarm buffer to display the Alarm buffer menu.
For details, see "Setting the Alarm Buffer — Alarm
buffer Menu" on page 64.
OK/Cancel
See "Buttons common to every menu" on page 30.
Periodical recording Tab — Setting
the periodical recording mode
You can set to record the image file (JPEG file) to a
"Memory Stick" or ATA memory card periodically.
Periodical recording
Select On when you want to use periodical recording.
Image file name
Type the file name of the image to be recorded to the
memory using up to 10 alphanumeric characters, -
(hyphen) and _ (under score).
The actual image file name will be the specified image
file name with the a suffix and the extension .jpg.
Note
You cannot record the audio file using the periodical
recording function.
Recording Images in Memory — Image memory Menu
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipela snc-rx550pIpela snc-rx550-b

Table of Contents