Download Print this page

Electrolux KSV26HRC Diagnostic Manual page 11

Split system air conditioner
Hide thumbs Also See for KSV26HRC:

Advertisement

Fault Code Description Continues:
E8, Indoor Unit. (Delayed)
Indoor Standby LED, flash 8 times. (Delayed)
Red LED, Outdoor unit flashing 3 times.
(Anti-High Temperature Protection)
# Check the indoor coil for airflow obstructions.
# Check the indoor fan motor for correct operation.
H1, Indoor unit.
Indoor Heating flashing 1 time.
Yellow LED: Outdoor unit, flashing 2 times.
(Defrosting)
PL, Indoor unit.
Yellow LED: Outdoor unit, flashing 12 times.
(Low Voltage Protection)
# Check supply voltage.
PH, Indoor unit.
Yellow LED, Outdoor unit flashing 13 times.
(High Voltage Protection)
# Check supply voltage.
HC, Indoor unit.
Indoor Heating LED, flash 6 times.
(PFC Protection)
# Check supply voltage.