USB-6008/6009 User Guide and Specifications
The USB-6008/6009 ships with one detachable screw terminal block for
analog signals and one detachable screw terminal block for digital signals.
These terminal blocks provide 16 connections that use 16 AWG to
28 AWG wire.
Table 2 lists the analog terminal assignments, and Table 3 lists the digital
terminal assignments.
Table 2. Analog Terminal Assignments
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Signal,
Single-Ended Mode
GND
AI 0
AI 4
GND
AI 1
AI 5
GND
AI 2
AI 6
GND
AI 3
AI 7
GND
AO 0
AO 1
GND
8
Signal,
Differential Mode
GND
AI 0+
AI 0–
GND
AI 1+
AI 1–
GND
AI 2+
AI 2–
GND
AI 3+
AI 3–
GND
AO 0
AO 1
GND