H From a surface facing a terminal.
I
From a terminal facing a terminal.
J
From an opening (door/window) in a carport into dwelling.
K Vertically from a terminal on the same wall.
L Horizontally from a terminal on the same wall.
Q Below horizontal hinged windows.
Page 14
7.9 Flue Dimensions
The standard horizontal flue kit allows for flue lengths between 100mm and 1m from elbow to
terminal
(Fig.
10).
Fig. 10
The maximum permissible equivalent flue length is:
7.10 Flue Terminal Trim
1. Once the flue is secure the trim can be fitted if required.
2. Remove the protective backing from the adhesive seal. Apply the seal to the rear of the
trim flange
(Fig.
11).
*
where the exhaust is directed upwards, otherwise 1000.
System 35/80 IE 5 metres
System 60/100 IE 4 metres
600
1200
1200
1500
300
*
3000