Location; Ventilation Of Compartments; Installation - Baxi 35/80 IE Installation & Servicing Instructions Manual

Gas fired wall mounted system boiler
Table of Contents

Advertisement

Fig. 6
1. A flat vertical area is required for the installation of the boiler.
2. These dimensions include the necessary clearances around the boiler for case removal,
spanner access and air movement. Additional clearances may be required for the passage of
pipes around local obstructions such as joists running parallel to the front face of the boiler.

7.4 Location

1. The boiler may be fitted to any suitable wall with the flue passing through an outside wall or
roof and discharging to atmosphere in a position permitting satisfactory removal of
combustion products and providing an adequate air supply. The boiler should be fitted within
the building unless otherwise protected by a suitable enclosure i.e. garage or outhouse. (The
boiler may be fitted inside a cupboard-see
Section
7.5).
2. If the boiler is sited in an unheated enclosure then it is recommended to leave the
On/Off/Reset Selector Switch in the domestic hot water and central heating position to give
frost protection.
3. If the boiler is fitted in a room containing a bath or shower reference must be made to the
current edition of I.S. 813 and the current ETCI Rules. If the boiler is to be fitted into a building
of timber frame construction then reference must be made to the current edition of Institution
of Gas Engineers Publication IGE/UP/7 (Gas Installations in Timber Framed Housing).
Page 12

7.5 Ventilation of Compartments

1. Where the appliance is installed in a cupboard or compartment, no air vents are required.
The appliance will run sufficiently cool without ventilation.