Power Supply

001 - START
Power off the system unit.
Check that the power cord for continuity. Replace if necessary.
Check for the correct line voltage from the power outlet, and verify
that the voltage selector switch (if present) is set to the correct
voltage.
Power on the system unit.
002 - DOES THE POWER SUPPLY FAN RUN? (YES, GO TO STEP 003.
NO, GO TO STEP 004)
003 - DOES THE SYSTEM FAIL TO SHUT OFF WHEN THE ON/OFF
SWITCH IS PRESSED? (YES, READ AHEAD. NO, GO TO STEP
005)
You might have a damaged on/off switch cable assembly.
Disconnect the on/off switch cable assembly connector from the
power supply connector and take an ohm reading.
Go to step 007.
004 -
Disconnect the power cord from the back of the system unit.
Disconnect all power and switch cable connectors from the system
board and the power supply.
Disconnect the power connectors to all drives.
Make a connection (jumper) between the black and white wires of
the standby power control cable as shown in the following figure.
Figure 2- 1
Standby Power Cable