Wells SS206 Owner's Manual page 7

Drop-in and bottom-mount unshrounded warmers with infinite switch control
Hide thumbs Also See for SS206:
Table of Contents

Advertisement

4.
For "bottom-mounted" warmers (i.e. warmers mounted to a
formed flange from underneath the counter top), apply a bead of
food-grade silicone sealant to the top inside lip of the pan prior to
attaching to the counter flange.
4.
For "top-mounted" warmers (i.e. warmers mounted from above
the counter top):
a. Verify that provided sealants are applied to the underside
of the warmer top flange prior to setting the unit into the
cutout.
b. After installation, verify that the tabs on the Wellsloks are
turned out to lock the warmer into the counter
c. Apply a thin bead of food-grade silicone sealant around the
flange to seal it to the counter.
ELECTRICAL INSTALLATION
1.
Refer to the product nameplate. Verify the electrical service
power. Voltage and phase must match the nameplate specifica-
tions. Wiring the warmer to the wrong voltage can severely dam-
age the unit or cause noticeably decreased performance.
2.
Available electrical service amperage must meet or exceed the
specifications listed on the specification sheet provided with the
warmer.
3.
Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked "GND" or "
NOTE: Wire gauge, insulation type and temperature rating , as well
as type, size and construction of conduit, must meet or exceed appli-
cable specifications of local codes and of the National Electrical
Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1.
IMPORTANT: All plumbing installations must be performed by a
qualified plumber.
2.
For units equipped with a DRAIN LINE: Some jurisdictions may
require an approved air gap or other back-flow prevention device
in the drain. It is the responsibility of the plumber to determine
such requirement, to provide and properly install the required
device.
INSTALLATION
7
NOTE: Damage caused by
leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
" .
IMPORTANT:
Contact a licensed electrician
to install and connect electrical
power to the appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT: Electrical
installation other than as
specified on the specification
sheet will void the UL listing,
and may void the warranty.
NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss206eSs206edSs206dSs206erSs206erd

Table of Contents